AXI 22 AT and AXI 44 AT • Remote Control
38
Object ID (OID) Number and Value Range Tables
Gain values should be entered as an unsigned integer. Attenuation values should be entered
as negative integers.
NOTES:
•
Gain values range from 0 dB to 42 dB and must be in 3 dB steps
.
For example:
0
,
3
,
6
,
9
, and so on.
•
Attenuation values must be in 1 dB steps.
Input
OID
Gain Value Range
Output
OID
Attenuation Value
Range
Mic/Line Input 1
40000
0
to
42
Output 1
60000
0
to -
100
Mic/Line Input 2
40001
0
to
42
Output 2
60001
0
to -
100
Mic/Line Input 3
40002
0
to
42
Output 3
60002
0
to -
100
Mic/Line Input 4
40003
0
to
42
Output 4
60003
0
to -
100