Warning
To avoid high voltage shock, do not open the device while the power is on.

GEFAHR

Das eingeschaltete Gerät darf nicht geöffnet werden, da andernfalls das Risiko eines

Stromschlags mit Hochspannung besteht.

DANGER

Afin d'éviter tout choc électrique, n'ouvrez pas l'appareil lorsqu'il est sous tension.

PELIGRO

Para evitar una descarga de alto voltaje, no abra el dispositivo mientras esté

encendido.

Warning
Make sure the rack housing the device is adequately secured to prevent it from becoming
unstable or falling over.

GEFAHR

Stellen Sie sicher, dass das Gestell für die Unterbringung des Geräts auf

angemessene Weise gesichert ist, so dass das Gestell oder der Schrank nicht wackeln

oder umfallen kann.

DANGER

Vérifiez que le bâti abritant le dispositif est bien fixé afin qu'il ne devienne pas

instable ou qu'il ne risque pas de tomber.

PELIGRO

Verifique que el bastidor que alberga el instrumento está asegurado correctamente

para evitar que pueda hacerse inestable o que caiga.

Warning
Make sure that the power source circuits are properly grounded, then use the power cord
supplied with the device to connect it to the power source.

GEFAHR

Stellen Sie sicher, dass die Stromkreise ordnungsgemäß geerdet sind. Benutzen Sie

dann das mit dem Gerät gelieferte Stromkabel, um es an die Srromquelle

anzuschließen.

DANGER

Vérifiez que les circuits de sources d'alimentation sont bien mis à la terre, puis utilisez

le cordon d'alimentation fourni avec le dispositif pour le connecter à la source

d'alimentation.

PELIGRO

Verifique que circuitos de la fuente de corriente están conectados a tierra

correctamente; luego use el cordón de potencia suministrado con el instrumento

para conectarlo a la fuente de corriente

Warning
Before beginning the installation, see the precautions in “Power precautions.”

GEFAHR

Vor der Installation siehe Vorsichtsmaßnahmen unter “Power Precautions”

(Vorsichtsmaßnahmen in Bezug auf elektrische Ablagen).

DANGER

Avant de commencer l'installation, consultez les précautions décrites dans “Power

Precautions” (Précautions quant à l'alimentation).

PELIGRO

Antes de comenzar la instalación, consulte las precauciones en la sección “Power

Precautions” (Precauciones sobre corriente).

Warning
Be careful not to accidently insert your fingers into the fan tray while removing it from the
chassis. The fan may still be spinning at a high speed.

GEFAHR

Die Finger dürfen nicht versehentlich in das Ventilatorblech gesteckt werden, wenn

dieses vom Gehäuse abgenommen wird. Der Ventilator kann sich unter Umständen

noch mit hoher Geschwindigkeit drehen.

DANGER

Faites attention de ne pas insérer vos doigts accidentellement dans le boîtier du

ventilateur lorsque vous le retirez du châssis. Il est possible que le ventilateur tourne

encore à grande vitesse.

PELIGRO

Procure no insertar los dedos accidentalmente en la bandeja del ventilador cuando

esté desmontando el chasis. El ventilador podría estar girando a gran velocidad.

Warning
For safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor.

GEFAHR

Aus Sicherheitsgründen sollte ein EGB-Armband zum Schutz von elektronischen

gefährdeten Bauelementen mit einem 1 Megaohm-Reihenwiderstand ausgestattet

sein.

DANGER

Pour des raisons de sécurité, la dragonne ESD doit contenir une résistance de série 1

méga ohm.

PELIGRO

Por razones de seguridad, la correa de muñeca ESD deberá contener un resistor en

serie de 1 mega ohmio.

Warning
If the installation requires a different power cord than the one supplied with the device, make
sure you use a power cord displaying the mark of the safety agency that defines the
regulations for power cords in your country. The mark is your assurance that the power cord
can be used safely with the device.

GEFAHR

Falls für die Installation ein anderes Stromkabel erforderlich ist (wenn das mit dem

Gerät gelieferte Kabel nicht passt), müssen Sie sicherstellen, dass Sie ein Stromkabel

mit dem Siegel einer Sicherheitsbehörde verwenden, die für die Zertifizierung von

Stromkabeln in Ihrem Land zuständig ist. Das Siegel ist Ihre Garantie, dass das

Stromkabel sicher mit Ihrem Gerät verwendet werden kann.

DANGER

Si l'installation nécessite un cordon d'alimentation autre que celui fourni avec le

dispositif, assurez-vous d'utiliser un cordon d'alimentation portant la marque de

l'organisation responsable de la sécurité qui définit les normes et régulations pour les

cordons d'alimentation dans votre pays. Cette marque vous assure que vous pouvez

utiliser le cordon d'alimentation avec le dispositif en toute sécurité.

PELIGRO

Si la instalación requiere un cordón de corriente distinto al que se ha suministrado

con el instrumento, verifique que usa un cordón de corriente que venga con la marca

de la agencia de seguridad que defina las regulaciones para cordones de corriente en

su país. Esta marca será su garantía de que el cordón de corriente puede ser utilizado

con seguridad con el instrumento.

Warning
Disconnect the power cord from all power sources to completely remove power from the
device.

GEFAHR

Ziehen Sie das Stromkabel aus allen Stromquellen, um sicherzustellen, dass dem

Gerät kein Strom zugeführt wird.

DANGER

Débranchez le cordon d'alimentation de toutes les sources d'alimentation pour

couper complètement l'alimentation du dispositif.

PELIGRO

Para desconectar completamente la corriente del instrumento, desconecte el cordón

de corriente de todas las fuentes de corriente.

Warning
This device might have more than one power cord. To reduce the risk of electric shock,
disconnect all power cords before servicing.

GEFAHR

Dieses System ist möglicherweise mit mehr als einem Netzkabel ausgestattet.

Trennen Sie stets die Verbindung aller Netzkabel, bevor Sie Wartungsarbeiten

durchführen, um dieGefahr eines Stromschlags auszuschließen.

DANGER

Ce commutateur peut comporter plusieurs cordons d'alimentation. Pour réduire les

risques de choc électrique, déconnectez tous les cordons d’alimentation avant

d’effectuerl’entretien de l’appareil.

PELIGRO

Este conmutador podría tener más de un cable de alimentación. Para reducir el

riesgo de sufrir una descarga eléctrica, desconecte todos los cables de alimentación

antes de proceder con la reparación.

Warning
Use safe lifting practices when moving the product.

GEFAHR

Beim Bewegen des Produktes ist auf eine sichere Hubtechnik zu achten.

DANGER

Utiliser des techniques de levage sûres pour déplacer le produit.

PELIGRO

Tenga mucho cuidado al levantar el producto para moverlo

Warning
Mount the devices you install in a rack as low as possible. Place the heaviest device at the
bottom and progressively place lighter devices above.

GEFAHR

Montieren Sie die Geräte im Gestell so tief wie möglich. Platzieren Sie das schwerste

Gerät ganz unten, während leichtere Geräte je nach Gewicht (je schwerer desto

tiefer) darüber untergebracht werden.

DANGER

Montez les dispositifs que vous installez dans un bâti aussi bas que possible. Placez le

dispositif le plus lourd en bas et le plus léger en haut, en plaçant tous les dispositifs

progressivement de bas en haut du plus lourd au plus léger.

PELIGRO

Monte los instrumentos que instale en un bastidor lo más bajos posible. Ponga el

instrumento más pesado en la parte inferior y los instrumentos progresivamente más

livianos más arriba.

Warning
All fiber-optic interfaces use Class 1 lasers.

GEFAHR

Alle Glasfaser-Schnittstellen verwenden Laser der Klasse 1.

DANGER

Toutes les interfaces en fibre optique utilisent des lasers de classe 1.

PELIGRO

Todas las interfaces de fibra óptica utilizan láser de clase 1.

Warning
Laser Radiation. Do Not View Directly with Optical Instruments. Class 1M Laser Products.

GEFAHR

Laserstrahlung! Schauen Sie nicht direkt mit optischen Instrumenten in den

Laserstrahl herein. Klasse 1M Laserprodukte.

DANGER

Rayonnement de laser. Ne regardez pas directement avec des instruments optiques.

Produits de laser de classe 1M.

General dangers

Cautions and Danger Notices

98

ExtremeSwitching SLX 9150 Hardware Installation Guide

Summary of Contents for ExtremeSwitching SLX 9150

Page 1: ...ExtremeSwitching SLX 9150 Hardware Installation Guide 9036306 00 Rev AC July 2020...

Page 2: ...etworks and the Extreme Networks logo are trademarks or registered trademarks of Extreme Networks Inc in the United States and or other countries All other names including any product names mentioned...

Page 3: ...er Supply 20 750 W DC Power Supply 20 Preparing for the Installation 21 Preparing for the Installation 21 Operating Environment Requirements 22 Meeting Building and Electrical Codes 22 Setting up the...

Page 4: ...58 Activating and Verifying the Switch 60 Activating and Verifying the Switch 60 Establishing a serial connection 60 Configuring the Switch for Use 62 Monitoring the Switch 63 Monitoring the Switch 63...

Page 5: ...wer Supply Units and Connecting Power 85 Selecting Power Supply Cords 86 Battery Notice 87 Regulatory Statements 88 CE statement 88 China ROHS 88 Canadian requirements 88 China CCC statement 89 Austra...

Page 6: ...identified in the text When a feature function or operation pertains to a specific hardware product the product name is used When features functions and operations are the same across an entire produc...

Page 7: ...defined in the text Italics are also used when referring to publication titles New information In a PDF this is searchable text Table 3 Command syntax Convention Description bold text Bold text indica...

Page 8: ...guidance from GTAC Call GTAC For immediate support 800 998 2408 toll free in U S and Canada or 1 408 579 2826 For the support phone number in your country visit www extremenetworks com support contact...

Page 9: ...rrors or confusing or conflicting information Improvements that would help you find relevant information in the document Broken links or usability issues If you would like to provide feedback you can...

Page 10: ...m The following table describes the ExtremeSwitching SLX 9150 Switch Models Table 4 SLX 9150 Switch Models Part number Description Introduced OS Currently supported SLX9150 48Y 8C ExtremeSwitching SLX...

Page 11: ...ower supply Back to Front airflow SLX OS 20 1 1 Yes XN DCPWR 750W F Modular 750W DC power supply Front to Back airflow SLX OS 20 1 1 Yes XN DCPWR 750W R Modular 750W DC power supply Back to Front airf...

Page 12: ...orage USB port standard A plug Sound Pressure Maximum MAC addresses 96 000 Maximum VLANs 4 096 Maximum ACLs 2 048 Maximum members in a standard LAG 64 Maximum per port priority pause level 8 Maximum n...

Page 13: ...tization and Tagging IEEE 802 1v VLAN Classification by Protocol and Port IEEE 802 1AB Link Layer Discovery Protocol LLDP IEEE 802 3x Flow Control Pause Frames IEEE 802 3ae 10 GBASE X IEEE 802 3 10 GB...

Page 14: ...ports The SLX 9150 Series switches include the following hardware features Table 10 SLX 9150 Switch Hardware Features Model SLX 9150 48Y SLX 9150 48XT Ports 48 1 10 25GbE SFP28 ports 8 40 100GbE QSFP2...

Page 15: ...de Shock half sine 98 m s2 10 G 11ms 9 shocks Random vibration 3 to 500 Hz at 1 5 G rms The front panel of the SLX 9150 48Y Switch includes 48 10 25 gigabit Ethernet ports capable of supporting passiv...

Page 16: ...ow direction The following illustration shows the rear view of the SLX 9150 48Y Switch Figure 3 SLX 9150 48Y Switch rear view with power supply and fan assemblies The following illustration shows the...

Page 17: ...rder to free the Management Set for removal Nonport side view of the SLX 9150 Switch The Nonport side view or rear panel of the SLX 9150 Switch includes Two power supply bays for 750 W AC or DC power...

Page 18: ...evice using any of the management options listed in the following table Table 11 Management options for the device Management tool Out of band support In band support Reference documents Command line...

Page 19: ...tory certifications There are no user serviceable parts inside the power supply and fan assembly Caution Ensure that the airflow direction of the power supply unit matches that of the installed fan tr...

Page 20: ...ower supply see Installing a 750 W Internal AC Power Supply on page 51 LEDs on the 750 W DC power supply provide information on the unit s operational status See 750 W AC Power Supply LEDs on page 65...

Page 21: ...moving any components of the system and before carrying out any maintenance procedures read the safety information in Safety and Regulatory Information on page 83 The information in this chapter is in...

Page 22: ...codes consult the following organization International Code Council ICC 5203 Leesburg Pike Falls Church VA 22041 USA www iccsafe org The organizations who are the authorities on electrical codes are...

Page 23: ...is easily accessible for installation and service See Rack Specifications and Recommendations on page 25 for more information Use appropriate AC or DC power power distribution and grounding for your...

Page 24: ...asures a temperature lower than the maximum specified ambient temperature at which time the system restarts automatically Alternately you can restart the system immediately by removing and then restor...

Page 25: ...ing the Rack The rack must be properly grounded Use a rack grounding kit and a ground conductor that is carried back to earth or to another suitable building ground At a minimum follow these guideline...

Page 26: ...is usually accomplished by turning off a circuit breaker Disconnecting the DC power cable from the DC power source must be done by a qualified licensed electrician Depending on other conditions in th...

Page 27: ...t panel of your Extreme Networks equipment and other hardware Keep accurate and current cable identification records Post records near each equipment rack For each cable drop include information about...

Page 28: ...ments Consult your local building codes to determine when it is appropriate to use plenum rated cable or refer to IEC standard 850 Keep all ports and connectors free of dust Figure 9 Properly Installe...

Page 29: ...Types below shows one example of cable media types and maximum distances that support reliable transmission in accordance with international standards except where noted Refer to Extreme Networks Plu...

Page 30: ...ble 150 10 Mbps link Category 5 and higher UTP cable 250 10GBASE SR SFP 850nm optical window 62 5 mm multimode fiber 160 26 62 5 mm multimode fiber OM1 200 33 50 mm multimode fiber 400 66 50 mm multim...

Page 31: ...to QSFP Direct attach cable AA1404037 E6 0 5 meter AA1404029 E6 1 meter AA1404030 E6 2 meters AA1404031 E6 3 meters AA1404032 E6 5 meters QSFP to QSFP Active optical cable AA1404028 E6 10 meters acti...

Page 32: ...le 250 Using RJ45 Connector Jackets Use RJ45 cable with connector jackets that are flush with the connector or that have connectors with a no snag feature Using cable with jackets that are wider than...

Page 33: ...ing situations Attaching UTP cable to AC power cables Routing UTP cable near antennas such as a ham radio antenna Routing UTP cable near equipment that could exhibit RF interference such as ARC weldin...

Page 34: ...ices do not ship with power cords Visit www extremenetworks com product powercords for information on selecting and purchasing the correct power cords for use with specific Extreme Networks equipment...

Page 35: ...tion Time UPS transition time is the time required for the UPS to change from providing AC power derived from the utility or mains supply to providing AC power derived from the battery backup UPS tran...

Page 36: ...569 A design considerations ANSI TIA EIA 606 cabling system administration ANSI TIA EIA 607 commercial building grounding and bonding requirements You can access these standards at www ansi org or ww...

Page 37: ...d with the switch A two post kit can be ordered separately The installation process includes the following tasks 1 Prepare to install the switch See What You Will Need for the Installation on page 38...

Page 38: ...cal Specifications on page 72 for additional information regarding regulatory compliance certifications What You Will Need for the Installation Ensure that you have followed the guidance in Preparing...

Page 39: ...e switch is attached to the rack refer to Removing the Switch from the Rack on page 68 if you need to remove it Attaching the Switch to a Four Post Rack A four post rack mounting kit is included in th...

Page 40: ...bracket to one side of the switch housing Snap the mounting bracket onto the housing Then anchor it in place using the screws provided See figure Attaching a Mounting Bracket to One Side of the Switc...

Page 41: ...st until they snap into place See the figure Attaching the Slider Assembly to the Front Rack Post Figure 13 Attaching the Slider Assembly to the Front Rack Post b Extend the slider assembly until its...

Page 42: ...rear rack posts on the other side 8 On both sides locate the sliding rails intermediate members in the slider assemblies and pull them out to their full extent See Figure Extending the Slider Assembly...

Page 43: ...the Mounting Brackets with the Rail Assemblies 12 Release the tabs on both slider assemblies and slide the switch back until it is firmly in place Screw the mounting ear thumbscrews into the rack rail...

Page 44: ...lies using the instructions in Installing a 750 W Internal AC Power Supply on page 51 Attaching the Switch to a Two Post Rack You can attach your switch to a two post rack in either of two configurati...

Page 45: ...unt position the bracket over the holes so that the flange ear is even with the front of the switch as shown in the figure below Attaching a Short Mounting Bracket Ear Front of Switch Figure 19 Attach...

Page 46: ...he other short mounting bracket to the other side of the switch housing as you did in step 2 3 Attach a long mounting bracket to one side of the switch housing and to the rack post a Position the long...

Page 47: ...e other side of the switch 5 Tilting the switch slightly lift it into the rack so that the mounting brackets align with the rack posts If the switch cannot be tilted because other equipment is mounted...

Page 48: ...Rack mounting screws are not provided The completed installation is shown in the diagrams below Two Post Front Mount Complete and Two Post Mid Mount Complete Figure 23 Two Post Front Mount Complete A...

Page 49: ...0 Series switches support the use of pluggable transceivers and cables in the SFP SFP28 QSFP and QSFP28 formats For a list of the optical components supported with SLX 9150 Series and SLX9250 Series s...

Page 50: ...SR4 INT with fiber breakout cables and additional 10GbE optics 40G QSFP ESR4 with fiber breakout cables and additional 10GbE optics For 4x 25GbE breakout cables 100G QSFP 4SFP P XXX For the SLX 9150...

Page 51: ...install a 750 W AC power supply in a switch follow these instructions All installed power supplies must have the same airflow direction front to back or back to front and must match the airflow direc...

Page 52: ...ly on page 51 Figure 26 Installing a 750 W AC Power Supply 5 Push the power supply in until the latch snaps into place Do not slam the power supply into the switch Note If power supplies are not insta...

Page 53: ...lace Figure 27 Power Supply with Power Cord and Retainer Attached d Snap the clip firmly around the connector 7 Connect the other end of the power cord to an AC power outlet Warning Always make sure t...

Page 54: ...a 750 W DC Power Supply You need the following tools and materials to install or remove a 750 W DC power supply in an SLX 9150 or SLX 9250 Series switch 14 AWG copper cable for grounding the power sup...

Page 55: ...efore installing a 750 W DC power supply part no XN DCPWR 750W F or XN DCPWR 750W R Verify that the switch chassis has been grounded See Grounding the Switch Chassis on page 55 Verify that the airflow...

Page 56: ...ply for the slot location Figure 28 Slots for Connecting Wires to the 750 W DC Power Supply a Insert the stripped end of the ground wire all the way into the slot b Insert a 1 Phillips screwdriver int...

Page 57: ...o the diagram below Slots for Connecting Wires to the 750 W DC Power Supply for slot locations Figure 29 Slots for Connecting Wires to the 750 W DC Power Supply b Insert a 1 Phillips screwdriver into...

Page 58: ...ear of the switch d Energize the circuit 3 When power is connected verify that the PSU LED turns green When the PSU LED has turned green follow the instructions in Connecting Network Interface Cables...

Page 59: ...s or other switches or I O modules 6 Dress and secure the cable bundle to provide appropriate strain relief and protection against bends and kinks Installing Your Switch Connecting Network Interface C...

Page 60: ...le port on the device complete the following steps 1 Verify that the device is powered on by verifying that all power LED indicators on the management and interface ports power supply and fan modules...

Page 61: ...a terminal emulator application such as HyperTerminal on a PC or TERM Tip or Kermit in a LINUX environment and configure the application as follows In a Windows environment Parameter Value Bits per s...

Page 62: ...Warning Access to the Root and Factory accounts may be required for proper support of the switch Please ensure the Root and Factory passwords are documented in a secure location Recovery of a lost Roo...

Page 63: ...on page 65 750 W DC Power Supply LEDs on page 66 SLX 9150 Series Switch LEDs The following illustrations show the port side views of the SLX 9150 Switch models showing the port and system LEDs 1 10 25...

Page 64: ...LEDs for Data Ports 1 48 Port Configuration Color State Meaning 10 25 Gb Steady green Port OK Blinking green Port transmitting or receiving Slow blinking green Port disabled by software Off No link Fa...

Page 65: ...diagnostic software Off Unit not operational PWR Power Steady green Normal operation Blinking green System in reset Off Unit not operational Table 20 SLX 9150 48Y Front Panel 100 1G RJ45 Port LEDs La...

Page 66: ...DC power supply part number XN DCPWR 750W F or XN DCPWR 750W R The LEDs are located on the end of the power supply unit arranged vertically to the left of the terminal block Table 22 750 W DC Power S...

Page 67: ...o match the airflow direction of the fan modules To replace one or both AC internal power supplies in an SLX 9150 or SLX 9250 switch follow the steps in Installing a 750 W Internal AC Power Supply on...

Page 68: ...flow have red tabs and are labeled Air Out Fans with back to front airflow have blue tabs and are labeled Air In 4 Carefully slide the replacement fan module into the switch Push until the fan module...

Page 69: ...witch from the Slider Assemblies b Disengage the retainers that are connecting the mounting brackets with the sliding rails on both sides c Carefully slide the switch out of the slider assembly and pl...

Page 70: ...s from the rear rack post See the diagram below Removing the Slider Assembly Rear Rack Post Figure 34 Removing the Slider Assembly Rear Rack Post Removing the Switch from the Rack Removing and Replaci...

Page 71: ...the weight of the switch unscrew the mounting brackets from the rack b Tilt the switch so that the brackets are clear of the rack posts and carefully lift it out of the rack If the switch cannot be t...

Page 72: ...10GE 1GE 8x100GE 40GE with dual power supplies and six fans SLX9150 48Y 8C AC R SLX9150 48Y Switch AC with Back to Front Airflow Supports 48x25GE 10GE 1GE 8x100GE 40GE with dual power supplies and six...

Page 73: ...ss support Storage USB port standard A plug Sound Pressure Maximum MAC addresses 70 000 Maximum VLANs 4 096 Maximum ACLs IPv4 IPv6 L2 2 000 Maximum members in a standard LAG 64 Maximum number of MCT s...

Page 74: ...ghts and Physical Dimensions Table 24 SLX 9150 Unpackaged Dimensions SLX 9150 48XT or SLX 9150 48Y Height 4 34 cm 1 71 in Width 43 96 cm 17 31 in Length 53 95 cm 21 24 in XN FAN 001 F Fan unit front t...

Page 75: ...th 22 1 cm 8 70 in Table 27 SLX 9150 Packaged Weight SLX 9150 48Y switch with no PSUs 14 59 kg 32 17 lb SLX 9150 48Y switch with two AC PSUs F and R models 16 24 kg 35 80 lb Fan unit front to back or...

Page 76: ...nown Tray 4 Fan 1 up high speed Unknown Tray 4 Fan 2 up medium speed Unknown Tray 5 Fan 1 up high speed Unknown Tray 5 Fan 2 up medium speed Unknown Tray 6 Fan 1 up high speed Unknown Tray 6 Fan 2 up...

Page 77: ...issipation BTU hr Fans high all ports 100 traffic Maximum Power Consumption Watts Fans high all ports 100 traffic SLX9150 48Y AC 553 BTU hr 167W 1600 BTU hr 469W SLX9150 48Y DC 553 BTU hr 167W 1600 BT...

Page 78: ...2001 IEC EN 60825 1 2007 IEC EN 60825 2 2004 A1 A2 or later Lasers Safety IEC 62368 1 2014 2ndEd IEC 60950 1 2005 2nd Ed Am 1 2009 Am 2 2013 National Difference Table 36 EMI EMC Standards North Ameri...

Page 79: ...SPER 32 2015 Class A GB T9254 2008 Class A ANSI C63 4 2014 Country specific RCM Australia VCCI Class A Japan MSIP KCC Korea BSMI Taiwan ANATEL Brazil CCC mark China SABS NRCS South Africa UL FCC North...

Page 80: ...vibration 3 to 500 Hz at 1 5 G rms Storage transportation conditions packaged Transportation temperature 40 C to 70 C 40 F to 158 F Humidity 5 to 95 relative humidity non condensing Packaged shock ha...

Page 81: ...73 in 750 W power supply DC front to back or back to front airflow Height 44 5 cm 17 52 in Width 27 5 cm 10 83 in Depth 42 5 cm 16 73 in Table 43 750 W Power Supplies Packaged Weight 750 W power supp...

Page 82: ...90 relative humidity non condensing Operational shock 30 m s2 3 G Power Cord Requirements for AC Powered Switches and AC Power Supplies An AC power cord is not included with the AC power supply Power...

Page 83: ...all equipment For equipment designed to operate in a typical Telco environment that is environmentally controlled choose a site that has the following characteristics Temperature controlled and humidi...

Page 84: ...top of the equipment The chassis cover is not designed to support weight To reduce the risk of fire use only 26 AWG or larger telecommunications line cord Use only copper conductors Do not work on the...

Page 85: ...d to each building grounding electrode system Caution Failure to follow these requirements for cable routing conditions may expose the user to electrical shock and expose the unit to damage that can c...

Page 86: ...fore connecting or disconnecting the DC power cord at the DC input power socket Connect the system or power supply only to a DC power source that complies with the safety extra low voltage SELV requir...

Page 87: ...ce Warning This product contains a battery used to maintain product information If the battery should need replacement it must be replaced by Service Personnel Please contact Technical Support for ass...

Page 88: ...evice contains the CE mark which indicates that this system conforms to the provisions of the following European Council directives laws and standards Electromagnetic Compatibility EMC Directive 2014...

Page 89: ...Warning This equipment is compliant with Class B of CISPR 32 In a residential environment this equipment may cause radio interference Regulatory Statements China CCC statement ExtremeSwitching SLX 91...

Page 90: ...ed to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user s au...

Page 91: ...English translation of above statement ATTENTION Never use the power cord packed with your equipment for other products Regulatory Statements Japan power cord ExtremeSwitching SLX 9150 Hardware Insta...

Page 92: ...n oder Besch digung der Hardware Firmware Software oder auch vor einem m glichen Datenverlust Un message de mise en garde vous alerte sur des situations pouvant pr senter un risque potentiel de dommag...

Page 93: ...ento de las normas la licencia del usuario para operar este equipo puede quedar anulada Caution Disassembling any part of the power supply and fan assembly voids the warranty and regulatory certificat...

Page 94: ...dem Buchstaben I gekennzeichnet MISE EN GARDE Veillez ce que le sens de circulation de l air du bloc d alimentation corresponde celui du tiroir de ventilation install Les blocs d alimentation et les t...

Page 95: ...ch digt MISE EN GARDE Utilisez les vis mentionn es dans les instructions L utilisation de vis plus longues peut endommager l appareil PRECAUCI N Utilice los tornillos especificados en el procedimiento...

Page 96: ...en Bedingungen und Situationen zu warnen Un nonc de danger indique des conditions ou des situations potentiellement mortelles ou extr mement dangereuses Des tiquettes de s curit sont pos es directemen...

Page 97: ...EFAHR Die f r die RTC NVRAM Sicherung verwendeten Batterien befinden sich nicht in f r den Bediener zug nglichen Bereichen Bei Ersetzen der Batterie durch einen falschen Typ besteht Explosionsgefahr E...

Page 98: ...the power cord supplied with the device to connect it to the power source GEFAHR Stellen Sie sicher dass die Stromkreise ordnungsgem geerdet sind Benutzen Sie dann das mit dem Ger t gelieferte Stromka...