Callout
Description
A
KT-135628-01 adapter
B
KT-135628-01 T-bar holder
C
KT-135628-01 adapter locking pin
3 Slide the KT-135628-01 T-bar holder onto the T-bar and replace the tiles to hold the adapter onto the
T-bar.
4 Hold and rock the access point back and forth to ensure that it is securely mounted.
5 Attach the RJ45 connector to the GE1 port.
Install the Access Point on a Flat T-bar Using the DCFLUSH bracket
Ensure that the T-bar meets the following conditions before installing the DCFLUSH bracket on it:
•
T-bar width must be 9/1 in. (15mm), 15/16 in. (24mm), or 1.5 in. (38 mm).
•
T-bar bottom must be flat all the way across.
•
T-bar must be structurally sound.
•
T-bar maximum base thickness must not exceed 0.080 in. (2 mm).
•
Ceiling tile must be flat all the way across.
•
Maximum ceiling tile protrusion allowed is 0.015 in. (0.380 mm).
The WS-MBI-DCFLUSH (#37211) bracket is used on a flat T-bar when you do not want to use the main
mounting bracket on it.
1 Remove the ceiling panels around the T-bar.
2 Open the movable sliding part of the DCFLUSH bracket to give the stationary and slider T-bar more
space.
Figure 6: DCFLUSH bracket parts and T-bar
Install the Access Point
ExtremeMobility™ Access Points AP410i/e
20