The BlackDiamond 6800 switch is suited for use in a wiring closet or equipment room,
where it can be mounted in a standard 19-inch equipment rack. Mounting brackets are
integrated with the chassis.
When deciding where to install the BlackDiamond 6800 switch, ensure that
•
The switch is accessible and cables can be connected easily.
•
Water or moisture cannot enter the chassis.
•
Air-flow around the unit and through the vents at the front, side, and rear of the
chassis is not restricted. A minimum of 3 inches is required (5 inches recommended)
for clearance.
•
Temperature operating limits of 0° to 40° C are not exceeded.
I
NSTALLING
THE
B
LACK
D
IAMOND
6800 S
WITCH
The BlackDiamond 6800 switch can be mounted in a rack. The chassis is 15U high and
fits in most standard 19-inch racks.
The BlackDiamond 6800 chassis is shipped empty; you must install the power supply
and modules after rack-mounting the empty chassis.
Warning: Rack-mount the chassis before installing any BlackDiamond 6800
switch components.
To install the BlackDiamond 6800 switch, follow these steps:
1
Mount the helper bracket in the rack using four appropriate rack-mounting screws,
as shown in
Figure 2-1
.
Summary of Contents for BlackDiamond 6800
Page 6: ...vi ...
Page 8: ...viii ...
Page 12: ...XII BLACKDIAMOND SWITCH HARDWARE INSTALLATION GUIDE PREFACE ...
Page 32: ...1 20 BlackDiamond Switch Hardware Installation Guide BLACKDIAMOND 6800 SWITCH OVERVIEW ...
Page 44: ...2 12 BLACKDIAMOND SWITCH HARDWARE INSTALLATION GUIDE INSTALLATION AND SETUP ...
Page 52: ...3 8 BLACKDIAMOND SWITCH HARDWARE INSTALLATION GUIDE SERVICE AND MAINTENANCE ...
Page 56: ...A 4 BLACKDIAMOND SWITCH HARDWARE INSTALLATION GUIDE SAFETY INFORMATION ...