24

ENGLISH

FrOnt aIr

This menu allows the upper ventilation motor speed to be set. 

Range: (AuTo, coMFoRT, oFF).

If comfort mode is selected, the upper air speed is reduced. If off mode is selected, the upper air is turned off.

To set: OK >FrONT aIr>SeT

easy set-Up

The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change without altering 

pellet quality. By using the eASY SeT-up function, it is possible to change the calibration of the volumetric weight by increasing or decreasing 

the preset values.

In the stove program, the available values range from “– 3” to “+ 3”; all stoves are calibrated during production with the optimal value, which 

is 0.

If you notice an excessive deposit on the burn pot, access the eASY SeT-up program and lower the value by one unit to “- 1”; then wait until 

the next day and if there is no improvement, decrease again, to a maximum of “- 3”. Instead, if it is necessary to increase the calibration of the 

volumetric weight of the pellet, change the factory value from “0” to “+ 1, + 2, + 3” as required.

To set: 

OK  > eaSy SeT-Up

EXcESSiVE PELLEt DEPoSit in BuRn Pot

noRMaL oPERation

MiniMuM PELLEt DEPoSit in BuRn Pot

-3

-2

-1

0

+1

+2

+3

THIRd decReASe 

RAnge IF THe 

FIRST TWo ARe 

InSuFFIcIenT

Second 

decReASe 

RAnge IF 

THe FIRST IS 

InSuFFIcIenT

FIRST decReASe 

RAnge (TeST FoR 

1 dAY)

opTIMAl FAcToRY 

vAlue

FIRST IncReASe 

RAnge

Second 

IncReASe RAnge 

IF THe FIRST IS 

InSuFFIcIenT

THIRd IncReASe 

RAnge IF THe 

FIRST TWo ARe 

InSuFFIcIenT

n.B.: iF tHESE aDJuStMEntS Do not SoLVE tHE PRoBLEM oF PELLEt DEPoSitS in tHE BuRn Pot, PLEaSE contact youR LocaL 

SERVicE cEntRE.

aIr ZOne cOntrOl

This menu allows you to enable the AIR Zone conTRol mode

Range: (on, oFF)

If on is selected, the stove will optimise the adjustment so that the heat is sent to the ducting when the main room temperature set is 

reached.

To set: OK > aIr ZONe CONTrOL > SeT

aIr dUctInG

This menu allows you to set the ducting motor speed. Range: (AuTo, coMFoRT, oFF).

If coMFoRT mode is selected, the ducting speed is reduced. If off mode is selected, the ducting is turned off.

To set: OK >aIr DUCTINg>SeT 

mOdes

This menu allows you to set the machine operation logic. Range: (AuToMATIc, SelF conTRol)

If AuToMATIc mode is selected, the stove power will be automatically adjusted to reach the set temperature without exceeding it.

this function improves the experience of using the generator in terms of consumption, thermal and acoustic comfort and the 

reduction in the need for cleaning and maintenance.

If SelF conTRol mode is selected, the stove will heat the room to the set temperature whilst maintaining the power set by the user.

To set: OK > mODe > SeT

Summary of Contents for SHARON PLUS

Page 1: ...MADE IN ITALY design production sharon plus UK pellet stoves USER MANUAL 004280809 Rev 000...

Page 2: ...ENGLISH APPLY TECHNICAL DATA LABEL 2...

Page 3: ...AND LOGIC 23 MODES 24 FRONT air 24 AIR DUCTING 24 AIR ZONE CONTROL 24 easy set up 24 CHRONO 25 ENABLING 25 prg 1 4 25 SETTINGS 27 DISPLAY 27 STAND BY 27 OPERATION WITH ADDITIONAL THERMOSTAT OPTIONAL...

Page 4: ...RATIFAvant de d placer le po le retirer le rev tement indiqu pour viter tout dommage de ACHTUNG PFLICHT Bevor der Ofen bewegt wird muss die angezeigte Verkleidung entfernt werden um Sch den zu vermei...

Page 5: ...ance has been installed as well as the instructions contained in this manual The use of the appliance must comply with all local regional national and European regulations The Manufacturer cannot be h...

Page 6: ...IF IT IS DISCONNECTED FROMTHE MAINS It is advised to position the power supply cable so that it does not come into contact with hot parts ofthe appliance The power supply plug must be accessible afte...

Page 7: ...clean the majolicas it is recommended to use a soft dry cloth If a detergent or liquid is used the latter could penetrate inside the crackles highlighting them SINCE THE PRODUCT CAN TURN ON AUTOMATICA...

Page 8: ...mestichotwaterproductionandinadjacentandcommunicating rooms 3 where the depression measured in situ between the external and internal environment is greater than 4 Pa N B Watertight appliances can als...

Page 9: ...always be insulated The smoke ducts must have at least one airtight inlet for flue gas sampling All the sections of the flue gas duct must be accessible to inspection Inspection openings must be prov...

Page 10: ...This means that it is ideal for passive houses because it does not take air in from within the house combustion air To ensure the stove remains hermetically sealed the connection pipe for the combust...

Page 11: ...Rear ducting B Serial input J Combustion air inlet C Access to combustion chamber and ash drawer K 230 V power supply D FUSE L Additional thermostat input TA E On Off M Room air outlet F Spacer N Pell...

Page 12: ...Mandatory wall mount On the back of the machine there are spacers A which determine the minimum distance to maintain from any rear support The spacers must not be removed The generator must be fastene...

Page 13: ...f the generator in the factory The flue gas outlet can be moved to the rear by following the instructions in the chapter REAR FLUE GAS OUTLET ASSEMBLY the conversion of the upper flue gas outlet MUST...

Page 14: ...air ducting motor will switch OFF and switch on again when there is a new request SET configured to COMFORT the temperature setting is not visible Oncethespecificactivationthresholdhasbeenreachedandex...

Page 15: ...only for the time required to load the fuel and for maintenance Failure to comply with the above during operation will cause the display to show the following CLOSE HOPPER STOVE DOOR This indication...

Page 16: ...TS OR ANY OTHER MATERIAL WILL COMPROMISE STOVE FUNCTIONS VOIDING THE WARRANTY AND RELEASING THE MANUFACTURER OF LIABILITY Pellet hopper pressurised closure During stove operation the pellet hopper lid...

Page 17: ...io communication not available LED on radio communication available L4 Yellow LED LED on 5 power set by the user L2 Red LED LED off normal operation LED on alarm present L5 Yellow LED LED on 1 power s...

Page 18: ...ear on the display In this case repeat the procedure J The radio control device is already CONFIGURED with unit 0 IF THERE IS ANOTHER STOVE to avoid interferences A NEW CONFIGURATION MUST BE PERFORMED...

Page 19: ...nt The radio control device is fitted with an LCD backlit display The display remains lit for 5 seconds After a certain period of time in order to minimise battery consumption the display turns off sl...

Page 20: ...LAY Display text Temperature detected in room Set room temperature Power 1 5 Time Chrono active STAND BY active Battery low display text Time Indicates contact of the additional outdoor thermostat Tan...

Page 21: ...it is necessary to perform the following checks If it is intended to be connected to a hydraulic system it must be complete and fully functional and in compliance with the instructions given in the pr...

Page 22: ...F THE PRODUCT AND RESULT IN THE IMMEDIATE NULLIFICATION OF THE WARRANTY PERIOD In the event of wear or deterioration ask the after sales service to replace the part Replacement does not fall within th...

Page 23: ...adio control temperature probe If the contact is open fulfilled the stove works at minimum power If the contact is closed request the stove works at the set power If the setting is on HOT set above 37...

Page 24: ...TWO ARE INSUFFICIENT SECOND DECREASE RANGE IF THE FIRST IS INSUFFICIENT FIRST DECREASE RANGE TEST FOR 1 DAY OPTIMAL FACTORY VALUE FIRST INCREASE RANGE SECOND INCREASE RANGE IF THE FIRST IS INSUFFICIE...

Page 25: ...desired power Current day and time settings are essential for the correct operation of the Chrono To set OK chrono prgx ENABLING Allows the chrono and the different stove time slots to be enabled disa...

Page 26: ...3 1 02 00 23 00 08 00 16 30 t 22 18 2 1 26 ENGLISH Time slot 1 Start 02 00 Stop 23 00 Power 3 set temp 22 C Time slot 2 Start 08 00 Stop 16 30 Power 1 set temp 18 C Stove operation TIME SLOT Power Set...

Page 27: ...t power and WORK will be displayed on the screen OPERATION WITH ADDITIONAL THERMOSTAT OPTIONAL STAND BY function set to OFF FACTORY SETTING When the STAND BY function is not activated OFF if the stove...

Page 28: ...ecommended if there is an excessive formation of combustion residues in the flue during operation at reduced power see FLUE EXHAUST chapter Caution It is advisable to activate the EASY CONTROL functio...

Page 29: ...ly Contact the technical support service FAST ON OFF FLASHING 0 1s ON 0 1s OFF Stove not recognised Connection problem with the main stove card It is correct for the stove not to be recognised in the...

Page 30: ...ION optional The stove can control the room temperature through an additional thermostat optional After ignition by pressing key 6 or in chrono mode the stove will work to reach the set value on the t...

Page 31: ...ANING THE CERAMIC GLASS Never use abrasive or chemically aggressive detergents for cleaning The ceramic glass must be cleaned when the glass is completely cold To clean the ceramic glass simply use a...

Page 32: ...e soot on the refractory bricks Unblock all the holes in the burn pot 2 using the supplied poker Put the burn pot back in place and push it towards the hearth wall C Reposition the ash conveyor making...

Page 33: ...conditions By observing the cleaning schedule reserved to the user described in the use and maintenance manual the generator will be guaranteed correct combustion over time thus preventing any faults...

Page 34: ...Gaskets pellet hopper inspections ash drawer and door replace and apply silicone where indicated C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete em...

Page 35: ...larm The alarm can only be reset if the fumes motor has stopped and 15 minutes have passed since the alarm was displayed by pressing key 6 for 3 seconds Fumes motor Fault Fumes motor fault Contact aft...

Page 36: ...kindly asked to separate this equipment and or batteries or accumulators included from other types of waste and to arrange for disposal by the municipal waste service It is possible to ask your local...

Page 37: ...37 ENGLISH...

Page 38: ...38 ENGLISH...

Page 39: ...39 ENGLISH...

Page 40: ...0445 865911 39 0445 865912 info extraflame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manufactu...

Reviews: