14
ENGLISH
wITH prOBE (NTC 10K)
remove the jumper and connect the NTC probe in the room that needs to be temperature-controlled through air ducting.
3 control modes:
OPEratION IN aIr DUctING wItH tHErMOstat Or PrObE (OPtIONaL)
The stove is fitted with an independent motor for ducting. The connection of an external thermostat or temperature probe (NTC 10K) in the
input, located in the rear part of the stove, makes it possible to control the air ducting motor independently of the stove.
Suffice it to connect the thermostat/temperature probe and set the desired temperature.
For information on air ducting settings see chapter:"
Menu - Air ducting
"
wITH AMBIENT THErMOsTAT (OpTIONAL)
Remove the jumper and connect the ambient thermostat in the room that needs to be temperature-controlled through air ducting 1.
3 control modes:
OpErATION IN AIr DuCTING wITH AMBIENT THErMOsTAT (OpTIONAL)
SET configured to OFF
(the temperature setting is not visible)
The air ducting motor will remain off unless the fumes temperature exceeds the
normal operating temperatures
SET configured to AUTO
(the temperature setting is not visible)
Once the specific activation threshold has been reached and exceeded, at temperature
to be satisfied (CLOSED CONTACT) the air ducting motor will follow the stove settings.
When the temperature set on the thermostat is reached (OPEN CONTACT), the air
ducting motor will switch OFF and switch on again when there is a new request.
SET configured to COMFORT
(the temperature setting is not visible)
Once the specific activation threshold has been reached and exceeded, at temperature
to be satisfied (CLOSED CONTACT) the air ducting motor will follow the stove settings
but at a lower speed than in SET AUTO for increased acoustic/ambient comfort.
When the temperature set on the thermostat is reached (OPEN CONTACT), the
ducting motor will switch off and switch on again when there is a new request.
OpErATION IN AIr DuCTING wITH NTC prOBE 10KΩ (OpTIONAL)
SET configured to OFF
Set the desired temperature ( from 7 to 37 °C)
The air ducting motor will remain off unless the fumes temperature exceeds the
normal operating temperatures
SET configured to AUTO
Set the desired temperature ( from 7 to 37 °C)
Once the specific activation threshold has been reached and exceeded, at temperature
to be satisfied the air ducting motor will follow the stove settings.
When the temperature set in TEMPERATURE is reached, the air ducting motor will
switch OFF and switch on again when there is a new request.
SET configured to COMFORT
Set the desired temperature ( from 7 to 37 °C)
Once the specific activation threshold has been reached and exceeded, at temperature
to be satisfied the air ducting motor will follow the stove settings
but at a lower speed than in SET AUTO for increased acoustic/ambient comfort.
When the temperature set in TEMPERATURE is reached, the air ducting motor will
switch off and switch on again when there is a new request.