32
ENGLISH
Displays
Display
Reason
oFF
Generator off
sTaRT
The start-up phase is in progress
pelleT loaDinG
Continuous pellet feeding is in progress during the ignition phase
iGniTion
The ignition phase is in progress
pRepaRaTion
The PREPARATION phase is in progress
WoRK
The normal work phase is in progress
MoDUlaTion
The generator is working at minimum
**BURn poT CleaninG Automatic burn pot cleaning is in progress
Final CleaninG
The final cleaning is in progress
sTanD By
Generator off waiting for re-ignition due to an external thermostat
CoolinG -
sTanD By
A new ignition is attempted when the generator has just been switched off. When the generator switches off, one must wait for
the complete shutdown of the fumes motor, then clean the burn pot. The generator can only be re-ignited when these operations
have been performed.
H-oFF
Generator off due to water temperature over set.
**T-aMB
Displays the room temperature (in models with this function).
*T - oFF
Generator off waiting for re-ignition due to all requests met
BlaCK oUT
sTanD By
The generator is cooling after a power cut.
Once cooling is completed, it will re-start automatically
anTi-FReeZinG
The anti-freezing function is in progress as the H2O temperature is below the factory set threshold
the pump is active until the water reaches the pre-set factory par2°C
anTi-BloCK
The pump anti-block function is in progress (only if the generator has been in an OFF state for at least 96 hours); the pump is
activated for the time pre-set by the manufacturer, in order to prevent it from blocking
aUTo BloW
The automatic blow is active
Close
HoppeR-sToVe DooR
This indication means that you have 60 seconds to close the hatch/door and the pellet lid.
After 60 seconds have passed, the stove will enter “DEPR ALARM” during the ignition phase, while during normal operation, the
stove will enter "COOLING STAND BY" and then restart automatically when the conditions are met (cold stove, etc.).
alaRMs
Display
eXplanaTion
solUTion
Indicates the presence of an alarm.
On: indicates the presence of an alarm
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset only if the fumes motor has stopped and 15 minutes
have passed since the alarm was displayed, by pressing the key 1/ON/
for 3 seconds.
FUMes MoToR
FaUlT
Fumes motor fault
Contact after-sales centre
FUMes pRoBe
Fumes probe fault.
Contact after-sales centre
HoT FUMes
High fumes temperature
Check pellet feed (see “Pellet feed adjustment”). If the problem cannot be
solved, contact an authorised technician.
**CHaMB pRoBe
Chamber probe fault.
Contact the after-sales centre.
no
iGniTion
The pellet hopper is empty.
Pellet feed calibration inadequate.
Thermostat bulbs tripped.
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see “Pellet load adjustment”).
Check the procedures described in the “Ignition” chapter.
Check bulb thermostats (see chapter on Resetting)
* if there is an additional system data sheet
** on models with this function.