22
ENGLISH
addItIonal thermostat
n.B. : InstallatIon must Be performed By an authorIsed teChnICIan
There is a possibility to control the temperature of a room adjacent to the room where the stove has been placed; simply connect a thermostat
following the procedure described in the following section (it is advisable to place the optional mechanical thermostat at a height from
the ground equal to 1.50m). stove operation with the external thermostat connected in the clamp Ta can be different depending on the
activation or deactivation of the sTaND-BY function.
By factory default, the clamp Ta is jumpered, therefore it always has closed contact (on request).
addItIonal thermostat funCtIonInG wIth stand-By aCtIve
when the sTaND-BY function is active, the sTBY icon will be on. when the contact or external thermostat is not satisfied (open contact /
temperature reached), the stove will switch off. as soon as the contact or external thermostat switches to the "not satisfied" status (closed
contact / temperature to be reached) it will re-ignite.
nB: stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions. If the stove is
in
H-oFF
(water temperature reached), any additional contact or thermostat request will be ignored.
addItIonal thermostat operatIon wIth stand-By deaCtIvated
when the sTaND-BY function is not active, the sTBY icon will be off.
when the contact or external thermostat is satisfied (open contact / temperature reached), the stove will go to minimum. as soon as the
contact or external thermostat switches to the "not satisfied" status (closed contact / temperature to be reached) the stove will start to work
again at the pre-set power.
nB: stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions. If the stove is
in
H-oFF
(water temperature reached), any additional contact or thermostat request will be ignored.
addItIonal thermostat InstallatIon
switch the appliance off using the master switch positioned on the rear of the stove.
remove the plug from the socket.
refer to the wiring diagram and connect the two thermostat wires in the relevant terminals located on the back of the stove, one red
and one black (clamp Ta). each model may have a different terminal location on the back of the stove. the image is given as an
example.
J
to aCtIvate stand-By, refer to the “settInGs” Chapter
Summary of Contents for RAFFAELLA IDRO H15
Page 2: ...APPLY TECHNICAL DATA LABEL...