ENGLISH
alaRMs
Display
explanation
solution
Indicates the presence of an alarm.
On: indicates the presence of an alarm
Off: indicates the absence of alarms
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset by pressing button 1 for 3 seconds only if
the fumes motor has stopped and if 15 minutes have elapsed from
when the alarm was displayed.
aspiRat - faulty
Fault correlated to the flue gas
exhaust motor.
The restoration operations must be carried out by an authorised
technician.
fuMes pRoBe
Fault correlated to the fumes probe.
The restoration operations must be carried out by an authorised
technician.
CHaMBeR pRoBe
Failure related to the combustion
chamber probe.
The restoration operations must be carried out by an authorised
technician.
alaRM
fuMes oveRHeating
The flue gas temperature has
exceeded 310°C
Check pellet flow (see “Pellet feed adjustment”).
Check that the machine is clean, including the fumes passage.
Do not rest cloths on the machine.
Other restoration operations must be carried out by an authorised
technician.
DepR alaRM
The mechanical depression sensor
has tripped
Check closure of the door and pellet tank.
Check air vent.
Contact after-sales centre.
no
ignition
The pellet feed-box is empty.
Pellet feed calibration inadequate.
Incorrect installation
Check for the presence of pellets in the feed-box.
Adjust pellet flow (see “Pellet feed adjustment”).
Check the procedures described in the “Ignition” chapter.
Other restoration operations must be carried out by an authorised
technician.
BlaCk-out no ign.
No current during the ignition phase.
Take the stove to OFF conditions using key 1 and repeat the
procedure described in the "Ignition" chapter.
Other restoration operations must be carried out by an authorised
technician.
no pellets
In the work phase, the t° of the flue
gases has dropped below default
parameters
Check for the presence of pellets in the feed-box.
Regulate the pellet flow.
Other restoration operations must be carried out by an authorised
technician.
Cooling stanD-By
Attempt to release the alarm with
stove still in cooling mode.
Every time the stove displays one of the alarms listed above it will
switch-off automatically.
The stove will block any release attempt during this phase,
showing the alarm itself and ATTE alternately on the display. The
alarm can be reset by pressing button 1 for 3 seconds only if the
fumes motor has stopped and if 15 minutes have elapsed from
when the alarm was displayed.
augeR ContRol
alaRM
Anomalous functioning
of pellet feeding
Contact after-sales assistance
seRviCe
When this message appears, contact the authorised technician to carry out the routine cleaning of the
device.
If cleaning is not carried out, the message will be displayed at every ignition without, however, interrupting
the normal functioning of the stove.