SAFETY DEVICES
9
Chapter 3
SAFETY DEVICES
HOT AIR DISTRIBUTION FAN BREAKAGE
In case the fan stops for any reason, the stove automatically stops.
FLUE EXHAUST BREAKAGE
If the suction device stops, the electronic board immediately blocks the pellet supply.
PELLET FEED MOTOR BREAKAGE
If the motor reducer stops, the stove continues to function until the minimum cooling level is reached.
NO IGNITION
If a fl ame is not developed during the ignition phase, the appliance automatically attempts ignition again,
this time without pellet feeding.
If in this case also the fl ame has not developed, the appliance will signal the alarm relating to no ignition;
if machine re-ignition is attempted, this will show “
ATTE
” meaning “wait”, on the display.
This function reminds that before performing ignition, it must be ensured that the brazier is completely
free and clean.
TEMPORARY POWER CUT
After a brief power cut, the appliance re-ignites automatically. When there is no electricity, the stove may
give off a minimum amount of smoke inside the case for a period from 3 to 5 minutes. THIS DOES NOT
REPRESENT ANY RISK WITH REGARD TO SAFETY.
DOOR MICRO SWITCH
When the stove door is opened, a safety micro switch blocks fuel feeding.
ELECTRIC SAFETY
The stove is protected against strong current changes by a master fuse that is found in the rear part of the
stove. (2.5A 250V Delayed).
FLUE EXHAUST SAFETY DEVICE
An electronic pressure switch blocks stove functioning and takes it to alarm conditions.
PELLET TEMPERATURE SAFETY DEVICE
If there is overheating inside the feed-box this device blocks stove functioning; restoration is manual and
must be performed by an authorised technician.