ELISIR UTENTE PARAMETERS (BOARD 002272575)
35
Chapter 1
PELLETS (-20% +20%)
If the stove has functioning problems owing to the quantity of fuel, adjust pellet feeding directly from the
control board.
The problems correlated to the amount of fuel can be divided into 2 categories:
LACK OF FUEL
The stove can never develop a suitable fl ame, tending to remain very low even at high powers.
At minimum power the stove tends to almost switch off taking the stove into no pellet alarm
conditions.
When the stove displays the no pellet alarm, there may be non-burned pellets inside the brazier.
EXCESS FUEL
The stove develops a very high fl ame even at low power.
The panoramic glass is very dirty, obscuring it almost totally.
The brazier tends to become encrusted, blocking the holes for air intake due to the excessive pellet
feed, as it is only burned partially.
If the problem occurs after only a few MONTH CLOCKs ON FIRE, check that routine cleaning,
has been carried out correctly.
Controls procedure
Press button 5 until “
1.
SET CLOCK
“ appears on display D1.
Using buttons 2 and 3 select “
2.
UTENTE
“.
Press button 5 to access the menu.
3.
Using buttons 2 and 3 select “
4.
PELLET
“.
Press button 5 to access the menu.
5.
The following operations can be carried out from the menu:
6.
Using buttons 2 and 3 increase/decrease as wanted.
Using button 1 confirm and return to the higher menu.
The regulation to be performed is a percentage. Therefore a modifi cation of this parameter will lead to a
proportional variation of all stove feeding speeds: the increase/decrease varies by 5 points per time.
ADJUSTMENT TABLE
LACK OF FUEL
Increase the percentage value by 5 points and try the stove with the new calibration
for at least half an hour. If the problem is attenuated, but not solved, increase by
another 5 points. Repeat the operation until the problem is solved.
If the problem cannot be resolved, contact the after-sales service.
EXCESS FUEL
Decrease the percentage value by 5 points and try the stove with the new
calibration for at least half an hour. If the problem is attenuated, but not solved,
decrease by another 5 points. Repeat the operation until the problem is solved.
If the problem cannot be resolved, contact the after-sales service.