ENGLISH
funcTioninG anD loGic
J
no iGniTion alarm
firsT iGniTion coulD eVen fail as The auGer is empTy anD is noT alWays able To loaD The burn poT WiTh
The reQuireD amounT of pelleTs on Time To reGularly sTarT The flame.
if The problem occurs afTer only a feW monThs WorkinG, check ThaT rouTine cleaninG sTaTeD in The
sToVe bookleT, has been carrieD ouT correcTly.
iGniTion
Once the points listed previously have been checked, press key 1 for three seconds to ignite the stove. 15 minutes are given for
the ignition stage, after ignition and once the control temperature has been reached, the
stove interrupts the ignition phase and switches to the sTarT-Up mode.
sTarTinG
During the start-up stage, the stove stabilises combustion, increasing it gradually, to then start ventilation and switch to the
wOrK mode.
Work
During the work stage, the stove reaches the set power and works to reach the set room temperature. see following item.
ThermosTaT seTTinG aDjusTmenT
The room temperature setting can be set using buttons 4 and 5, from low-07 to 40°C -hot
loW - hoT
if the temperature setting is on “low” (set below the 7°C threshold) the stove will always function at minimum.
if the setting is on “hot” (set above the 40°C threshold) the stove will not modulate, always functioning and only at the set power.
poWer seTTinG aDjusTmenT
The power setting features 5 operating levels, via button 5, (access) 1 and 2 ( adjustment).
power 1 = minimum level - power 5 = maximum level.
Work WiTh room probe (sTanDarD)
The appliance controls the room temperature via a probe fitted on the appliance.
Once the the set temperature has been reached, it will automatically go to minimum or switch off activating the
stand by
function, reducing pellet consumption to a minimum.
By default the
sTby
function is always set on
off
(light
on).
For its activation and logic, follow the indications on the next page, chapter:
stand by.
burn poT cleaninG
During the work stage, the stove has an internal counter which cleans the burn pot after a set amount of time.
This stage will be shown on the display, it will bring the stove to a lower power level and will increase the fumes motor for a
programmed amount of time.
when the cleaning stage is finished, the stove will continue its work, going back to the selected power level.
sWiTch-off
press key 1 for three seconds.
when the operation has been performed, the appliance automatically enters the switch- off phase, blocking the supply of
pellets.
The fumes motor and the hot air ventilation motor will remain on until the temperature of the stove has dropped below
the factory parameters.
re-iGniTion
The stove can only be re-ignited if the flue gas temperature has lowered and the preset timer has been reset to zero.