ENGLISH
chrono
The chrono allows to program 2 time spans within a day to use every day of the week.
The switch-on and switch-off time can be set in every time slot, along with the days of use of
the programmed time slot.
reCOmmeNDaTiONs
The ignition and switch-off times must be within the arc of
one day, from 0 to 24 and not over several days:
Before using the chrono function, set the current day and
time. Therefore check that the points listed in the “
Set clock
”
sub-chapter have been followed, so that the chrono function
works. aside from programming it, activate it as well.
example:
switch-on time 07:00
correcT
switch-off time 18:00
switch-on time 22:00
incorrecT
switch-off time 05:00
reseT
allows to reset all values modifiable by the user to the default values. The modified data is the following:
CONTrOls prOCeDUre
press key 5 and
seT clock
will appear.
press key 3 several times until
user
is displayed.
press key 5.
press key 5 until "
reseT
" appears.
press keys 2 - 3 to select
on
and press key 5.
"
Done
" will appear on the display to confirm.
enable chrono
it allows to enable/disable the chrono and the various time slots.
CONTrOls prOCeDUre
press key 5 for a few seconds, until
seT clock
appears.
press key 3 several times to reach
enable chrono
.
press key 5, to confirm and use keys 2-3 to enable "
on
" or disable "
off
" the chrono.
Use keys 4 -5 to select the desired time slot.
press keys 2 - 3 to enable "
on
" or disable "
off
" the selected time slot.
press key 1 several times to confirm and exit the menu.
sTBy FUNCTiON seT aT ON
if the stby function is active (ON), when the stove reaches the set room temperature and exceeds it by 2°C, it will switch off
after a default delay time, displaying stand - by.
when the room temperature is 2°C lower than the setting, the stove will start to work again at the power set on the display,
displaying wOrK.
sTBy FUNCTiON seT aT OFF (DeFaUlT seTTiNg)
if the stby function is not active (OFF), if the stove reaches the set room temperature, it will go to minimum, modulating and
displaying mODUlaTe. when the room temperature is below the setting, it will start to work again at the set power and
displaying wOrK.
CONTrOls prOCeDUre
press key 5 for a few seconds, until seT ClOCK appears.
press key 3 three times UNTil User appears.
press key 5 twice.
select "ON" with keys 2 or 3 to activate or "OFF" to deactivate.
press key 1 several times to confirm and exit the menu.
22