PRODUCT DISPLAY TABLES
39
Chapter 9
Chapter 9
PRODUCT DISPLAY TABLES
SIGNALS
Signals
Reason
Solution
Display
ATTE
A new ignition is attempter when the stove has
just been switched off (normal switch-off or
caused by an alarm).
When the stove switches off (normal or caused by
an alarm) it is necessary to wait until it cools down
completely, therefore clean the brazier.
The stove can only be re-ignited when these
operations have been performed.
HOT
Room thermostat set at maximum value.
In this mode the stove does not work with a
temperature level but works in manual with 5
powers. To escape this function just lower the
room temperature using button 2.
LOU
Room thermostat set at minimum value.
In this mode the stove only works at 1st power
independently from the power set. To escape this
function just raise the room temperature using
button 3.
T ON
An external thermostat has been connected.
The room thermostat probe is disconnected.
The room thermostat probe is cut-off .
To exclude any external thermostat just disconnect
it.
Other restoration operations must be carried out
by an authorised technician.
STBY
Stove off waiting for re-ignition.
In this mode the machine can be switched on/off
using an additional thermostat (see “
Mechanical
thermostat function in energy saving mode
”).
To exclude the following function just raise the
room temperature using button 3.
DOFF
Stove off due to “
Day-night temperature function
”
and in Stand-by to re-ignite.
To exclude the re-ignition of the stove due to the
“
Day-night temperature function
” just hold button
1 down for 3 seconds, taking the stove to
OFF
.
To exclude the function completely, press button
4 and, holding it down, press 5.
DOFF
Stove off due to “
Day-night temperature function
”
and in Stand-by to re-ignite.
To exclude the re-ignition of the stove due to the
“
Day-night temperature function
” just hold button
1 down for 3 seconds, taking the stove to off .
To exclude the function completely, press button
4 and, holding it down, press 5.
RAF / BLAC OUT
No current on the main power supply.
After the complete cooling cycle the stove will re-
ignite automatically.
PUL
Automatic brazier cleaning is in progress.
The automatic brazier cleaning is performed at
pre-established intervals of continued working.
The automatic cleaning does not start if the stove
is in 1st power.