31
USER PARAMETERS
Chapter 7
Chapter 7
USER PARAMETERS
USER PARAMETERS
WEEKLY PROGRAMMER
Display D1
Display D2
Function
OFF
0
Activation/deactivation of the weekly programmer
00:00
1
Time 1st switch-on
00:00
2
Time 1st switch-off
OFF 1
3
Ignition/switch-off consents for various days
00
4
Installer parameter
00:00
5
Time 2nd switch-off
00:00
6
Time 2nd switch-off
OFF 1
7
Ignition/switch-off consents for various days
00:00
8
Time 3rd switch-on
00:00
9
Time 3rd switch-off
OFF 1
A
Ignition/switch-off consents for various days
DAY-NIGHT TEMPERATURE FUNCTION
Display D1
Display D2
Function
06:00
B
Start of day time/end of night time
22:00
C
Start of night time/end of day time
25
D
Day time max. temperature
20
E
Night time max. temperature
PELLET FEED ADJUSTMENT
Display D1
Display D2
Function
00
F
% pellet feed adjustment
DUCTING MOTOR % ADJSUTMENT
Display D1
Display D2
Function
ON
G
Parameter cannot be modifi ed
00
H
Ducting motor % adjustment
WEEKLY PROGRAMMER
The weekly programmer allows to program 3 time spans within a day to use every day of the week. The
ignition and switch-off times must be within the arc of one day, from 0 to 24 and not over several days:
E.g. switch-on
07:00/switch-off
18:00
OK
switch-on
22:00/switch-off
05:00
ERROR
First of all the current day and time must be set using the “
current day and time adjustment
” sequence to
give a reference to the function itself.
To switch programming on press 3, hold it down and press 5 and then release both keys together. Move
using key 5 until a fl ashing “0” appears on display D2.
The following table gives all weekly programmer function parameters.
Summary of Contents for Comfort Plus
Page 2: ...2 ...
Page 4: ...4 ...
Page 22: ...35 mm 35 mm 60 mm 22 COMFORT PLUS INSTALLATION Chapter 4 figure 4 7 figure 4 8 ...
Page 45: ...45 Notes ...
Page 46: ...46 Notes ...
Page 47: ...47 Notes ...