35
USER PARAMETERS
Chapter 7
The various parameters must only be set with the stove off !
Summary table
Display D1
Display D2
Function
06:00
B
Start of day time/end of night time
22:00
C
End of day time/start of night time
25°C
D
Day time max. temperature
20°C
E
Night time max. temperature
Once the function is activated the machine must be ignited using key 1.
When the stove switches off due tot he maximum temperature reached, “
DOFF
” will appear on display D1.
The stove switches back on automatically when the room temperature lowers by 3°C with respect to the
maximum temperature set.
E.g.
State of the stove –
DOFF
Maximum temperature set - 25°C
When the room temperature falls below 22°C (25 – 3 = 22 °C), the stove will re-start automatically.
The stove can only re-ignite from the “DOFF” state and not from the “OFF” state.
The manual controls, from the display or remote control, always remain priority with respect to
programming.
PELLET FEED ADJUSTMENT
If the stove has functioning problems owing to the quantity of pellets, adjust pellet feeding directly from
the control board.
The problems correlated tot he amount of fuel can be divided into 2 categories:
LACK OF FUEL:
the stove can never develop a suitable fl ame, tending to remain very low even at high powers.
at minimum power the stove tends to almost switch off taking the stove into alarm conditions “
NO
PELL
”.
when the stove displays the “
NO PELL
” alarm, there may be non-burned pellets inside the brazier.
EXCESS FUEL:
the stove develops a very high fl ame even at low power.
the panoramic glass is very dirty, obscuring it almost totally.
the brazier tends to become encrusted, blocking the holes for air intake due to the excessive pellet
feed, as it is only burned partially.