30
ENGLISH
J
a Clean burn Pot guarantees CorreCt oPeration!
by keePing the burn Pot and its holes Constantly Clean and free of
Combustion residue, exCellent Combustion is guaranteed over time,
thus Preventing any generator malfunCtions that may reQuire
teChniCal assistanCe.
the "easy setuP" funCtion in the user menu Can be used to adaPt
Combustion to sPeCifiC needs.
BURN POT HOLES
routine maintenanCe Performed by Qualified teChniCians
routine maintenance must be performed at least once a year.
Given the generator uses pellets as solid fuel, it requires annual routine maintenance, which must be performed by a
Qualified technician,
using only original spare parts.
Failure to comply may jeopardise the safety of the appliance and make the warranty null and void.
Respecting the frequencies of cleaning reserved for the user described in the use and maintenance manual, the generator is guaranteed
correct combustion over time, preventing any anomalies and/or malfunctioning that could require more interventions of the technician.
Requests for routine maintenance are not contemplated in the product warranty.
gaskets: Pellet hoPPer Cover, door, ash drawer and burn Pot
The gaskets ensure the stove is properly sealed consequently works properly.
They must be controlled periodically. They must be replaced immediately if they are worn or damaged.
These operations must be carried out by a qualified technician.
Cleaning the flue gas ComPartment
The flue gas compartment should be cleaned every two months or whenever necessary and at the end of the season.
ConneCtion to the flue
Annually, or in any case each time the fumes exhaust pipe needs to be aspirated and cleaned. If there are horizontal sections, the residue must
be removed to prevent it from obstructing the flow of fumes.
deCommissioning (end of season)
At the end of each season, before turning the stove off, it is advisable to empty the pellet hopper out completely, removing any pellet residue
and dust with a vacuum cleaner.
We also recommend disconnecting the generator from the mains and, for added safety especially when children are present, remove the
power cable.
Routine maintenance must be performed at least once a year.
One day means an average use of 8h at the rated power.
How often the ash drawer is emptied depends on a number of factors: the type of pellets, the stove output, the use of the stove and the
type of installation.
pARTS/FREqUENCY
EVERY 3 DAYS
EVERY YEAR
BURN pOT (USER)
x
COMBUSTION CHAMBER (USER)
x
ASH DRAWER (USER)
x
T-SHApED FITTING / SMOkE DUCT (TECHNICIAN)
x
TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE
WEBSITE: