Chapter 3 – Unpacking & Installation
User Manual
14
Vortex
®
Precedence
Rev 3.6
Package contents
Remove all shipping material and inspect the
contents for damage. Notify the shipping
company immediately if any damage is found.
Contact Extol to arrange for repair if necessary.
Compare the contents of the package with the
packing list provided.
Location & mounting
•
To lift the Vortex attach a 2000lb strap
to the lifting loop on top of the machine
column.
•
Lift with a forklift or crane and place the
Vortex on a flat, level, & stable work
surface capable of supporting the
machine‘s weight (approximately 325lbs
or 150kg).
•
Use the mounting holes provided in the
base of the machine to secure it to the
work surface with 10mm (3/8”) bolts.
Power connections
•
Use a plug to connect the required
electrical service to the machine. The
Vortex is capable of operating within the
range of 323-528 VAC, 50/60 Hz, 3
phase (240V option: 180-253 VAC,
50/60Hz, 3 phase). The Vortex is
internally fused at 12 Amperes (240V
option: 20 A).
•
The SCCR (Short Circuit Current Rating)
of this machine is 100,000 Amps.
•
Use a quick disconnect fitting to connect
the compressed air supply to the
machine. The Vortex requires 0.59 MPa
(85 psi) minimum of non-lubricated
dry air. A 10mm (3/8”) air line is
recommended to achieve adequate air
flow in applications where vacuum is
used.
•
Set the main air regulator to 0.59 MPa
(85 psi).
Tool Leveling, Centering, &
Mounting
Each Vortex is leveled and centered by Extol at
assembly and does not require re-alignment by
the customer. However, if the lower tool plate or
WARNING
Hazardous Voltage
Contact may cause electric shock
or burn. Installation should only
be performed by qualified
personnel.
WARNING
Lifting and the use of a Hi-Lo
should only be performed by
trained personnel. Do not use
straps that are worn or frayed.
Summary of Contents for VORTEX PRECEDENCE G1
Page 66: ...Chapter 6 Operation User Manual 60 Vortex Precedence Rev 3 6 Sequence of Operations Flowchart ...
Page 69: ...Chapter 6 Operation User Manual 63 Vortex Precedence Rev 3 6 ...
Page 88: ...Chapter 8 Troubleshooting User Manual 82 Vortex Precedence Rev 3 6 Servo Drive Alarms ...
Page 89: ...Chapter 8 Troubleshooting User Manual 83 Vortex Precedence Rev 3 6 ...
Page 90: ...Chapter 8 Troubleshooting User Manual 84 Vortex Precedence Rev 3 6 ...
Page 91: ...Chapter 8 Troubleshooting User Manual 85 Vortex Precedence Rev 3 6 Servo Drive Warnings ...
Page 104: ...651 Case Karsten Drive Zeeland MI 49464 1 800 324 6205 www extolinc com ...