UM200-en-GB_V1.5   2/17 

Meter Description 

Front Panel 

  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1. 

LCD: 

6000 count LCD with Backlight. 

2. 

 button: 

In SETUP mode, press the 

 button to increment value by 1. Press and hold the 

 

button for over 2 seconds to increment value swiftly. In Recall mode, press the 

 button to 

display the next stored data location. 

3. 

SELECT button: 

In SETUP mode press the 

SELECT

 button to select HI (Limit) or LO (Limit) 

or display cable resistance per foot or meter 

4. 

 button: 

In SETUP mode, press the 

 button to decrement value by 1. Press and hold the 

 button for over 2 seconds to decrement value swiftly. In Recall mode, press the 

 button to 

display the previously stored data data location) 

5. 

ZERO / RECALL button: 

In resistance mode, zero the range before making measurements. 

Press the 

ZERO / RECALL

 button to enter Relative mode (the present readings will be reset to 

zero), or press the

 ZERO / RECALL

 button for over 2 seconds to exit the Relative mode. In 

SETUP mode, use this button to recall the pre-stored sets of HI limits, LO limits and resistance 
per unit. 

6. 

START / STOP button: 

In resistance mode, press the 

START / STOP

 button to start 

measurement. Press the 

START / STOP

 button again to stop and hold the reading.  

7. 

REC / READ button: 

In measurement mode, press the 

REC / READ

 button to display the 

number of the present recorded data and have the present reading recorded. In SETUP mode, 
press the 

REC / READ

 button to enter READ data mode. Press it again to exit READ data 

mode. In the READ mode, users can recall data stored by pressing the 

 or 

 button. 

8. 

FEET / METERS button: 

In cable length mode, press the 

FEET / METERS

 button to select 

units of Meter (M) or Feet (FT). 

1

2
3
4
5
6

7

8

9

10

11

12
13
14

15

16

17

Summary of Contents for UM200

Page 1: ...User Manual Micro Ohmmeter Model UM200 Additional User Manual Translations available at www extech com ...

Page 2: ... ohmmeter Do not use the lithium battery to power anything but this instrument Do not soak or immerge the lithium battery in any liquid The lithium battery may explode if disposed of in Fire Recycled or disposed of the battery as directed by local regulations Do not expose the lithium battery to temperature higher than 60 C or 140 F Do not disassemble the lithium battery assembly Do not short circ...

Page 3: ...measurements Press the ZERO RECALL button to enter Relative mode the present readings will be reset to zero or press the ZERO RECALL button for over 2 seconds to exit the Relative mode In SETUP mode use this button to recall the pre stored sets of HI limits LO limits and resistance per unit 6 START STOP button In resistance mode press the START STOP button to start measurement Press the START STOP...

Page 4: ...ton to enable disable the backlight 14 button for 600mΩ 1A and 60mΩ 10A ranges Press to measure inductive materials when the LED is off 15 button Press the Beep button to turn on off the alarm function HI and LO When the alarm function is enabled the icon will be shown in LCD If the value of resistance is within the HI LO range a PASS will be displayed If the value of resistance is out of HI LO ra...

Page 5: ...r Clip Terminal or 4 wire Test Leads Terminal 2 P1 Alligator Clip Terminal or 4 wire Test Leads Terminal 3 P2 Alligator Clip Terminal or 4 wire Test Leads Terminal 4 C2 Alligator Clip Terminal or 4 wire Test Leads Terminal 5 Kelvin Clip Terminal 6 Kelvin Clip Terminal 7 POWER for the input of AC adaptor 1 2 3 4 1 2 3 4 5 6 7 ...

Page 6: ...light with inductance symbol is on this indicates the measurement is for both resistive materials and inductive materials When the LED light with inductance symbol is off inductive material cannot be measured NOTE The battery will not charge with the rotary switch in the OFF position Place the rotary switch in any range position to charge the battery Warning Do not measure any resistance object wi...

Page 7: ...together and press the Zero button The reading should read zero Ohms 4 Connect the test leads to the device under test 5 Press the START STOP button to start the measurement 6 The LCD will continuously display the value of the resistance Only resistive materials can be measured 7 If you need to change ranges Zero the range before making a measurement 8 To stop the measurement press the START STOP ...

Page 8: ... x10 button to move the decimal to the next position 7 To store the modified data the SELECT button NOTE If the reading of resistance is OL the unit will not indicate PASS or beep The alarm function works only when the resistance is within measuring range NOTE The limits of HI and LO alarms are 0 001mΩ and 999 99Ω The limits of Resistance per unit are 0 001μΩ ft or m 999 99Ω m 304 79Ω ft Cable Len...

Page 9: ...nce is 0 0 Ω is shown instead of 0 FT or m If the length is less than 0 0001 feet or meters but greater than 0 0 0001 feet or meters is shown Memory Record Read and Clear Record 1 With a reading in the display press the REC READ button 2 The memory location number will flash on the display and the data will be stored to that location Read 1 Turn the rotary switch to SETUP 2 Press the REC READ butt...

Page 10: ...battery part BATT 111V Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices to a desig...

Page 11: ...000mΩ 5 000mΩ to 60 000mΩ 1 A 4 00mΩ to 40 00mΩ 10μΩ 0 25 250μΩ 15 00mΩ to 160 00mΩ 50 00mΩ to 600 00mΩ 100 mA 0 0400Ω to 0 4000Ω 100μΩ 0 25 2 5mΩ 0 1500Ω to 1 6000Ω 0 5000Ω to 6 0000Ω 10 mA 0 400Ω to 4 000Ω 1 mΩ 0 25 25mΩ 1 500Ω to 16 000Ω 5 000Ω to 60 000Ω 1 mA 4 00Ω to 40 00Ω 10 mΩ 0 25 250mΩ 15 00Ω to 160 00Ω 50 00Ω to 600 00Ω 100μA 0 0400kΩ to 0 4000kΩ 100 mΩ 0 75 3Ω 0 1500kΩ to 1 6000kΩ 0 50...