background image

CA3010_CA3018

 

en

GB_V1.0

   

1/15

 

4

CAUTIONS

 

 

CAUTIONS

 

identify

 

conditions

 

and

 

actions

 

that

 

could

 

cause

 

DAMAGE

 

to

 

the

 

meter

 

or

 

equipment

 

under

 

test.

 

Do

 

not

 

expose

 

the

 

meter

 

to

 

extremes

 

in

 

temperature

 

or

 

high

 

humidity.

 

Safety

 

Symbols

 

that

 

are

 

typically

 

marked

 

on

 

meters

 

and

 

instructions

 

 

This

 

symbol,

 

adjacent

 

to

 

another

 

symbol,

 

indicates

 

the

 

user

 

must

 

refer

 

to

 

the

 

manual

 

for

 

further

 

information.

 

 

Do

 

not

 

apply

 

or

 

remove

 

clamp

 

from

 

HAZARDOUS

 

LIVE

 

conductors

 

 

Equipment

 

protected

 

by

 

double

 

or

 

reinforced

 

insulation

 

 

Battery

 

symbol

 

 

Conforms

 

to

 

EU

 

directives

 

 

Do

 

not

 

discard

 

this

 

product

 

in

 

household

 

trash.

 

 

AC

 

measurement

 

 

Earth

 

ground

 

 

PER

 

IEC1010

 

OVERVOLTAGE

 

INSTALLATION

 

CATEGORY

 

OVERVOLTAGE

 

CATEGORY

 

I

 

Equipment

 

of

 

OVERVOLTAGE

 

CATEGORY

 

I

 

is

 

equipment

 

for

 

connection

 

to

 

circuits

 

in

 

which

 

measures

 

are

 

taken

 

to

 

limit

 

the

 

transient

 

over

voltages

 

to

 

an

 

appropriate

 

low

 

level.

 

Note

 

 

Examples

 

include

 

protected

 

electronic

 

circuits.

 

OVERVOLTAGE

 

CATEGORY

 

II

 

Equipment

 

of

 

OVERVOLTAGE

 

CATEGORY

 

II

 

is

 

energy

consuming

 

equipment

 

to

 

be

 

supplied

 

from

 

the

 

fixed

 

installation.

 

Note

 

 

Examples

 

include

 

household,

 

office,

 

and

 

laboratory

 

appliances.

 

OVERVOLTAGE

 

CATEGORY

 

III

 

Equipment

 

of

 

OVERVOLTAGE

 

CATEGORY

 

III

 

is

 

equipment

 

in

 

fixed

 

installations.

 

Note

 

 

Examples

 

include

 

switches

 

in

 

the

 

fixed

 

installation

 

and

 

some

 

equipment

 

for

 

industrial

 

use

 

with

 

permanent

 

connection

 

to

 

the

 

fixed

 

installation.

 

OVERVOLTAGE

 

CATEGORY

 

IV

 

Equipment

 

of

 

OVERVOLTAGE

 

CATEGORY

 

IV

 

is

 

for

 

use

 

at

 

the

 

origin

 

of

 

the

 

installation.

 

Note

 

 

Examples

 

include

 

electricity

 

meters

 

and

 

primary

 

over

current

 

protection

 

equipment

 

Summary of Contents for CA3010

Page 1: ...USER GUIDE 3000A AC Flexible Clamp Adaptors Models CA3010 and CA3018...

Page 2: ...the 10 25 4cm clamp version otherwise both meters are the same These devices are professional CAT IV 600V CAT III 1000V instruments This meter is shipped fully tested and calibrated and with proper u...

Page 3: ...ments To reduce the risk of fire or electric shock do not expose this product to rain or moisture Verify the meter operation by measuring a known current If in doubt have the meter serviced Do not app...

Page 4: ...GE CATEGORY I Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over voltages to an appropriate low level Note Examples inc...

Page 5: ...d Caution statements in this operation manual prior to using this meter Meter Power The meter is powered by two 2 AAA 1 5V batteries located in compartment on bottom of meter handle Press the Power bu...

Page 6: ...chanism on the Clamp Adaptor counter clockwise to release the flexible clamp 6 Fully enclose only one conductor of the device under test with the flexible clamp probe see accompanying diagrams Do not...

Page 7: ...ry compartment 1 With a flat blade screwdriver or coin rotate the battery compartment cover to the unlock position 2 Remove the battery compartment cover 3 Replace the 2 AAA 1 5V batteries observing c...

Page 8: ...ified for a period of one year after calibration Max Output Voltage 4 5V peak Output Noise 5mV for each range Position Error of Clamp Accuracy and position error assumes centralized primary conductor...

Page 9: ...Altitude Maximum operating altitude 2000m 6562 Battery Two AAA 1 5V batteries Battery life 160 hours with alkaline batteries Dimensions W x H x D CA3010 120 x 280 x 25 mm 4 7 x 11 0 x 1 0 CA3018 130...