Maintenance

 

WARNING:

 

To

 

avoid

 

electrical

 

shock,

 

disconnect

 

the

 

meter

 

from

 

any

 

circuit

 

and

 

turn

 

OFF

 

the

 

meter

 

before

 

opening

 

the

 

case.

 

Do

 

not

 

operate

 

the

 

meter

 

with

 

an

 

open

 

case.

 

Cleaning

 

and

 

Storage

 

Periodically

 

wipe

 

the

 

case

 

with

 

a

 

damp

 

cloth

 

and

 

mild

 

detergent;

 

do

 

not

 

use

 

abrasives

 

or

  

solvents.

 

If

 

the

 

meter

 

is

 

not

 

to

 

be

 

used

 

for

 

60

 

days

 

or

 

more,

 

remove

 

the

 

batteries

 

and

 

store

 

them

 

separately.

 

Battery

 

Replacement

 

CAUTION:

 

Remove

 

the

 

meter

 

from

 

the

 

conductor

 

under

 

test

 

and

 

switch

 

the

 

meter

 

OFF

 

before

 

opening

 

the

 

battery

 

compartment.

 

 

1.

 

With

 

a

 

flat

 

blade

 

screwdriver

 

or

 

coin,

 

rotate

 

the

 

battery

 

compartment

 

cover

 

to

 

the

 

unlock

 

position.

 

2.

 

Remove

 

the

 

battery

 

compartment

 

cover.

 

3.

 

Replace

 

the

 

2

 

‘AAA’

 

1.5V

 

batteries

 

observing

 

correct

 

polarity.

 

Positive

 

side

 

of

 

both

 

batteries

 

insert

 

first.

 

4.

 

Re

attach

 

the

 

battery

 

compartment

 

cover.

 

5.

 

Rotate

 

the

 

battery

 

compartment

 

cover

 

to

 

the

 

lock

 

position.

 

 

You,

 

as

 

the

 

end

 

user,

 

are

 

legally

 

bound

 

(

EU

 

Battery

 

ordinance

)

 

to

 

return

 

all

 

used

 

batteries,

 

disposal

 

in

 

the

 

household

 

garbage

 

is

 

prohibited!

 

You

 

can

 

hand

 

over

 

your

 

used

 

batteries

 

/

 

accumulators

 

at

 

collection

 

points

 

in

 

your

 

community

 

or

 

wherever

 

batteries

 

accumulators

 

are

 

sold!

 

Disposal:

 

Follow

 

the

 

valid

 

legal

 

stipulations

 

in

 

respect

 

of

 

the

 

disposal

 

of

 

the

 

device

 

at

 

the

 

end

 

of

 

its

 

lifecycle

 

 

 

 
 

Summary of Contents for CA3010

Page 1: ...USER GUIDE 3000A AC Flexible Clamp Adaptors Models CA3010 and CA3018...

Page 2: ...the 10 25 4cm clamp version otherwise both meters are the same These devices are professional CAT IV 600V CAT III 1000V instruments This meter is shipped fully tested and calibrated and with proper u...

Page 3: ...ments To reduce the risk of fire or electric shock do not expose this product to rain or moisture Verify the meter operation by measuring a known current If in doubt have the meter serviced Do not app...

Page 4: ...GE CATEGORY I Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over voltages to an appropriate low level Note Examples inc...

Page 5: ...d Caution statements in this operation manual prior to using this meter Meter Power The meter is powered by two 2 AAA 1 5V batteries located in compartment on bottom of meter handle Press the Power bu...

Page 6: ...chanism on the Clamp Adaptor counter clockwise to release the flexible clamp 6 Fully enclose only one conductor of the device under test with the flexible clamp probe see accompanying diagrams Do not...

Page 7: ...ry compartment 1 With a flat blade screwdriver or coin rotate the battery compartment cover to the unlock position 2 Remove the battery compartment cover 3 Replace the 2 AAA 1 5V batteries observing c...

Page 8: ...ified for a period of one year after calibration Max Output Voltage 4 5V peak Output Noise 5mV for each range Position Error of Clamp Accuracy and position error assumes centralized primary conductor...

Page 9: ...Altitude Maximum operating altitude 2000m 6562 Battery Two AAA 1 5V batteries Battery life 160 hours with alkaline batteries Dimensions W x H x D CA3010 120 x 280 x 25 mm 4 7 x 11 0 x 1 0 CA3018 130...

Reviews: