background image

461700 / 461750 Version 2.3 Mar 2004 

4

461750 Safety Precautions 

The 461750 incorporates a finger guard for protection. However, care should be taken 
when measuring surface speed to avoid injury. 

1. Hold the meter firmly when touching the wheel or attachment to a moving object

2. Keep fingers behind the finger guard while taking measurements

3. Keep your eyes and attention on the measurement activity at all times

4. Do not attempt to record measurements while holding the meter to the moving object

(use the Data Hold feature to freeze the reading on the LCD; refer to the Data Hold
section of this manual).

Meter Power 

Power ON / OFF 

1. Press the triangular POWER HOLD button to turn the device ON. Alternatively, press

the button at the bottom of the meter (just under the LCD) which doubles as a power 
on/off button. Two buttons are provided for easy reach at any holding angle. 

2. Press and hold the triangular POWER HOLD button (or the alternate button) for

approx. 5 seconds to turn the device OFF. 

Auto Power OFF 

1. The meter turns off AUTOMATICALLY after 20 minutes.

2. For 461750 only: To disable this feature, turn the meter off. Then press and hold the

POWER and UNITS buttons until the meter turns on. Release the POWER button first
and the ‘n’ display icon will appear. This indicates that the feature is disabled.

actoolsupply.com

actoolsupply.com

Summary of Contents for 461700

Page 1: ...i Photo Tachometer Model 461700 Mini Contact Tachometer Model 461750 Extech 461700 PocketTach Mini Photo Tachometer Extech 461700 NIST PocketTach Mini Photo Tachometer actoolsupply com actoolsupply com actoolsupply com ...

Page 2: ...omatic range selection Time Base 4MHz Quartz Crystal Sampling Time 1 second 60 rpm 1 second 10 to 60 rpm Photo Tachometer Distance 2 to 12 5 to 30cm Operating Temperature 32 to 122 o F 0 to 50 o C Operating Humidity 80 RH Max Power supply 9V Battery Battery Life 40 hours approx Applicable standards EN 50081 1 1992 EN 55022 EN 50082 1 1997 EN 55024 Dimensions 461700 4 9 x 2 0 x 1 3 124 x 51 x 33mm ...

Page 3: ...cs 5 Hand Guard 461750 only 6 Power ON OFF and HOLD button 7 Unit of measure selection button 461750 only 8 LCD Display 9 Alternate Power ON OFF button Note that the battery compartment is located on the rear of the instrument Display Description 1 Low Battery 2 Data Hold 3 Rotations per minute 4 Meters per minute Feet per minute Yards per minute actoolsupply com actoolsupply com ...

Page 4: ...he Data Hold section of this manual Meter Power Power ON OFF 1 Press the triangular POWER HOLD button to turn the device ON Alternatively press the button at the bottom of the meter just under the LCD which doubles as a power on off button Two buttons are provided for easy reach at any holding angle 2 Press and hold the triangular POWER HOLD button or the alternate button for approx 5 seconds to t...

Page 5: ...esults The distance from meter to object can be up to 12 30cm 5 Read the RPM rotations per minute measurement on the LCD 461750 Contact Tachometer 1 Affix the convex cone or concave funnel attachment that best fits the application to the meter shaft as shown below 2 Turn the meter ON 3 Use the UNITS button to select RPM the display will reflect the selection 4 Touch the attachment to the moving ob...

Page 6: ...ct the unit of measure ft min feet per minute m min meters per minute yds min yards per minute Data Hold Feature After the meter is turned on the POWER HOLD button can be pressed and released to activate Data Hold Data Hold automatically freezes the displayed reading While the reading is held the HOLD display icon switches on Press the POWER HOLD button again to exit this mode Conveyor belt Touch ...

Page 7: ...warranty applies on sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department for authorization or visit our website click on Contact Extech and go to Service Department to request an RA number A Return Authorization RA number must be issued before any product is returned to Extech The sender i...