background image

401025-en-GB_v2.6   6/17 

Appendix A - Typical Light Levels 

Lux

 

Foot 
Candles

 

 

 

Lux

 

Foot 
Candles

 

 

 

 

Factories

 

   

 

Home

 

20-75 

2-7 

Emergency Stairs, 
Warehouse  

  100-150 

10-15 

Washing 

75-150 

7-15 

Exit/Entrance Passages 

  150-200 

15-20 

Recreational 
Activities 

150-300 

15-30 

Packing Work 

  200-300 

20-30 

Drawing Room, 
Table 

300-750 

30-75 

Visual Work: Production  
Line 

  300-500 

30-50 

Makeup 

750-1,500  75-150 

Typesetting: Inspection 
Work 

  500-1,500  50-150 

Reading, Study 

1,500-
3,000 

150-300 

Electronic  Assembly, 
Drafting 

  1,000-

2,000 

100-200 

Sewing 

 

 

Office

 

   

 

Restaurant

 

75-100 

7-10 

Indoor Emergency Stairs    75-150 

7-15 

Corridor Stairs 

100-200 

10-20 

Corridor Stairs 

  150-300 

15-30 

Entrance, Wash 
Room 

200-750 

20-75 

Conference, Reception 
Room 

  300-750 

30-75 

Cooking/Dining 
Room 

750-1,500  75-150 

Clerical Work 

  750-1,500  75-150 

Show Window 

1,500-
2,000 

150-2000 

Typing, Drafting 

   

 

 

 

 

Store

 

   

 

Hospital

 

75-150 

7-15 

Indoors 

  30-75 

3-7 

Emergency Stairs  

150-200 

15-20 

Corridor/Stairs 

  75-100 

7-10 

Stairs 

200-300 

20-30 

Reception 

  100-150 

10-15 

Sick Room, 
Warehouse 

300-500 

30-50 

Display Stand 

  150-200 

15-20 

Waiting Room 

500-750 

50-75 

Elevator 

  200-750 

20-75 

Medical Exam Room 

750-1,500  75-150 

Show Window, Packing 
Table 

  750-1,500  75-150 

Operating Room 

1,500-
3,000 

150-300 

Storefront, Show Window    5,000-

10,000 

500-1000 

Eye Inspection 

Appendix B - Common Terms and Conversion Factors 

Illuminance  (Visible Flux Density) 

1 lm/m2 =  

1 lux (lx) 
10-4 lm/cm2 
10-4 phot (ph) 
9.290 x 10-2 lm/ft2 
9.290 x 10-2 foot-candles 

Luminance (Visible Flux Density per Solid Angle) 

1 lm/m2/sr =  

1 candela/m2 

Luminous Intensity (Visible Flux per Solid Angle) 

1 lm/sr =  

1 candella 

Luminous Flux ( Visible Flux) 

1 lumen (lm) =   1.464 x 10-3 watts @ 555 nm 

 

Copyright 

©

 2013-2017 FLIR Systems, Inc. 

All rights reserved including the right of reproduction in whole or in part in any form 

ISO-9001 Certified 

www.extech.com 

Summary of Contents for 401025

Page 1: ...USER MANUAL Model 401025 Digital Light Meter Additional User Manual Translations available at www extech com ...

Page 2: ...proper use will provide years of reliable service Please visit our website www extech com to check for the latest version of this User Guide Product Updates and Customer Support Meter Description 1 LCD Display 2 Data Hold Switch 3 Power Off Range Switch 4 Analog Output Terminal 5 Battery Compartment rear 6 LUX Fc Switch Response Switch 7 Light Sensor 8 Zero adjust ...

Page 3: ...ld position The reading will freeze in the display until the Data Hold Switch is released Note 1 An Over Range indication is a display of 1__ If this occurs switch to a higher range Note 2 For measurements made on the Fc 5000 range the displayed reading must be multiplied by 10 Note 3 For measurements made on the Lux 20000 or 50000 ranges the displayed reading must be multiplied by 10 and 100 resp...

Page 4: ...d 1 Completely cover the sensor to block out any light 2 Set the range switch to the lowest Lux or Fc range 3 Using a small screwdriver adjust the Zero control for a zero display The last digit may change slightly This is normal and does not affect the accuracy of the meter Analog Output The analog output jacks on the front panel produce a 0 1mV DC per digit signal that can be used for recording o...

Page 5: ...er is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment Specifications General Specifications Display 13mm 0 5 LCD Liquid Crystal Display Measurement types Lux Ft candles Fc Ranges see range table below Lux 0 to 50 000 Lux in 3 ranges Foot candles 0 5 000 Fc in 3 ranges Sensor Exclusive photo diode color correction filter...

Page 6: ...000 Lux 2 000 19 990 Lux 10 Lux 5 2digits 50 000 Lux 20 000 50 000 Lux 100 Lux 5 2digits Foot candle Fc Range In range Display Resolution Accuracy FS 200 Fc 0 199 9 Fc 0 1 Fc 5 2digits 2 000 Fc 200 1 999 Fc 1 Fc 5 2digits 5 000 Fc 2 000 5 000 Fc 10 Fc 5 2digits Frequency Spectrum 300 400 500 600 700 800 1 0 8 0 6 0 4 0 2 0 Wavelength nm ...

Page 7: ...00 2 000 150 2000 Typing Drafting Store Hospital 75 150 7 15 Indoors 30 75 3 7 Emergency Stairs 150 200 15 20 Corridor Stairs 75 100 7 10 Stairs 200 300 20 30 Reception 100 150 10 15 Sick Room Warehouse 300 500 30 50 Display Stand 150 200 15 20 Waiting Room 500 750 50 75 Elevator 200 750 20 75 Medical Exam Room 750 1 500 75 150 Show Window Packing Table 750 1 500 75 150 Operating Room 1 500 3 000 ...

Reviews: