Range Specifications 

Lux

 

Range 

In-range Display 

Resolution 

Accuracy (FS) 

2,000 Lux 

0-1,999 Lux 

1 Lux 

± (5% + 2digits) 

20,000 Lux 

2,000-19,990 Lux 

10 Lux 

± (5 % + 2digits) 

50,000 Lux 

20,000-50,000 Lux 

100 Lux 

±- (5 % + 2digits) 

Foot-candle (Fc)

 

Range 

In-range Display 

Resolution 

Accuracy (FS) 

200 Fc 

0-199.9 Fc 

0.1 Fc 

± (5% + 2digits) 

2,000 Fc 

200-1,999 Fc 

1 Fc 

± (5% + 2digits) 

5,000 Fc 

2,000-5,000 Fc 

10 Fc 

± (5% + 2digits) 

 
 
Frequency Spectrum 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

300          400          500            600           700        800 


 
0.8 
 
0.6 
 
0.4 
 
0.2 
 

Wavelength (nm) 

Summary of Contents for 401025

Page 1: ...USER MANUAL Model 401025 Digital Light Meter Additional User Manual Translations available at www extech com ...

Page 2: ...proper use will provide years of reliable service Please visit our website www extech com to check for the latest version of this User Guide Product Updates and Customer Support Meter Description 1 LCD Display 2 Data Hold Switch 3 Power Off Range Switch 4 Analog Output Terminal 5 Battery Compartment rear 6 LUX Fc Switch Response Switch 7 Light Sensor 8 Zero adjust ...

Page 3: ...ld position The reading will freeze in the display until the Data Hold Switch is released Note 1 An Over Range indication is a display of 1__ If this occurs switch to a higher range Note 2 For measurements made on the Fc 5000 range the displayed reading must be multiplied by 10 Note 3 For measurements made on the Lux 20000 or 50000 ranges the displayed reading must be multiplied by 10 and 100 resp...

Page 4: ...d 1 Completely cover the sensor to block out any light 2 Set the range switch to the lowest Lux or Fc range 3 Using a small screwdriver adjust the Zero control for a zero display The last digit may change slightly This is normal and does not affect the accuracy of the meter Analog Output The analog output jacks on the front panel produce a 0 1mV DC per digit signal that can be used for recording o...

Page 5: ...er is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment Specifications General Specifications Display 13mm 0 5 LCD Liquid Crystal Display Measurement types Lux Ft candles Fc Ranges see range table below Lux 0 to 50 000 Lux in 3 ranges Foot candles 0 5 000 Fc in 3 ranges Sensor Exclusive photo diode color correction filter...

Page 6: ...000 Lux 2 000 19 990 Lux 10 Lux 5 2digits 50 000 Lux 20 000 50 000 Lux 100 Lux 5 2digits Foot candle Fc Range In range Display Resolution Accuracy FS 200 Fc 0 199 9 Fc 0 1 Fc 5 2digits 2 000 Fc 200 1 999 Fc 1 Fc 5 2digits 5 000 Fc 2 000 5 000 Fc 10 Fc 5 2digits Frequency Spectrum 300 400 500 600 700 800 1 0 8 0 6 0 4 0 2 0 Wavelength nm ...

Page 7: ...00 2 000 150 2000 Typing Drafting Store Hospital 75 150 7 15 Indoors 30 75 3 7 Emergency Stairs 150 200 15 20 Corridor Stairs 75 100 7 10 Stairs 200 300 20 30 Reception 100 150 10 15 Sick Room Warehouse 300 500 30 50 Display Stand 150 200 15 20 Waiting Room 500 750 50 75 Elevator 200 750 20 75 Medical Exam Room 750 1 500 75 150 Show Window Packing Table 750 1 500 75 150 Operating Room 1 500 3 000 ...

Reviews: