Power Unit
Nominal mains voltage
Maximum power consumption (60%)
Current taken from mains
(% 60)
(% 100)
Power factor (cos )
(% 60)
Output
Welding current
(% 60)
(%100)
Idling voltage range
Welding current setting range
Welding voltage setting range
Welding voltage grade number
Protection class
Radio noise level
Insulation class
Supply cable
Fuse value and type
Ambient operating temperature
Weight (excl. cables) (without coolant)
(with coolant)
Dimensions (Width x Height x Depth)
Wire Drive Unit
Wire drive speed (u ) range
n
Wire speed setting before welding
Wire diameters Steel wire (V type reels)
Flux cored wire (V type notched reels)
Supply voltage and power of wire drive unit
Maximum supply current
Protection class
Weight (excl. cables)
Dimensions (Width x Height x Depth)
MasterMIG 500W
380 V
10, 50/60 % Hz, 3 Phase
±
28.3 kVA
38 A
28 A
0.94
% 73.3
500 A, 39.0 V
387 A, 33.4 V
20 - 51 V
75 - 500 A
17.8 - 39 V
30 (3x10)
IP21S
W
F+H
4 x 10 mm²
3 x 63 A (delayed)
Between - 10 C and +40 C
°
°
207 kg
212 kg
645 x 905 x 1070 mm
MasterFeed MF-3
1 - 24 m/ min.
% 10 - % 100 (u)
n
0.8 - 1.0 - 1.2 mm
1.2 - 1.6 mm
42 V, 90 W
4 A
IP21
19 kg
290 x 440 x 675 mm
4 Technical Data
Page 17
Expressweld MasterMIG 500W
(for arc start without splashing)