background image

2.1

    MOUNTING

HANGING

UPRIGHT

The LED PAR can be mounted in an upright or 
sitting position using the supporting brackets.

The LED PAR can be mounted in a hanging position using the 
supporting bracket.  The bracket should be secured to the 
mounting truss or structure using a standard mounting clamp.  
Please note that when hanging the unit a safety cable should 
also be used.

@ 220V: 40 units may be connected in series

@120V: 20 units may be connected in series

The LED MODULE can be mounted at any angle and in any 
position.  It is possible to further adjust the angle of the LED 
MODULE using the two adjustment knobs located on the side of 
the fixture.

2.2

    POWER CONNECTIONS

5

2 INSTALLATION

Note:

  As this fixture's DMX signal  cable connection had been changed to 

Parallel connection, so if over 30 units to be connected, then a DMX signal 
amplifier is needed.

2

 

 

INSTALLATION

2009.12.9

12

3 DISPLAY PANEL OPERATION

2009.12.9

3.12

    SAVE

 
 

Only the main menu and the Auto-programs submenu can be protected
Repower the unit, it will back to the main menu

3.11

    PASSWORD

PASSWORD

ON/OFF

MENU

PASSWORD

 Enter the

PASSWORD

mode to select whether the access password is on or off.

 When the fixture is set as PASS 

ON

, after 30 seconds or turn on the fixture next 

    time, the fixture will need an access password to enter the display menu control. 

 

Note:

 The factory access password is

UP

+

DOWN

+

UP

+

DOWN

, then 

            press 

ENTER

to confirm the access.

3.10

    SETTINGS

MENU

ID

 

Reset to Factory?

 

Up load custom?

 

Up load custom?

Choose 

ON

/

OFF

 to open or close ID

This function will reset all setting to the original factory setting

Select

to upload the custom programs from the current 

     MASTER unit to the SLAVE units

 

COLOR

is  f ora  ctivate/unactivate t hec  olorc  alibrationf  unctions. When

    [

UC

] is selected, the RGB output are adjusted to a standard preset  universal 

    color  which balances fixtures from different generations..  
    The factory default  setting is [

UC

] on. 

SETTINGS

  ID

ON/OFF

Reset to
Factory?

Up load
costom?

  
COLOR

  
UC

  
OFF

Summary of Contents for TourSport 21 CM

Page 1: ...T o u r S p o t 2 1 C M Ma n u a l...

Page 2: ...n error 2 Power switch damaged 3 Display board damaged 1 Check all power connections 2 Replace power switch 3 Replace display board LED MODULE on but no control from display 2 Display board damaged 2...

Page 3: ...12 input Independant ID address Stand alone Slave 1 PRODUCT GENERAL 1 1 PRODUCT GENERAL 2009 12 9 4 3 BASIC INSTRUCTIONS FOR DMX512 OPERATION STAGE 1 MASTER DIMMER CH1 controls the intensity of the cu...

Page 4: ...100 240V 50 60Hz 35W 1 PRODUCT GENERAL 2 Environment Temperature 20 40 2009 12 9 9 ID21 ID22 210 211 CHANNEL FUNCTION VALUE 15 4 USING ADMX512 CONTROLLER ID20 200 209 2009 12 9 ID64 ID65 ID66 253 254...

Page 5: ...HANNEL FUNCTION VALUE 14 4 USING ADMX512 CONTROLLER ID ADDRESS ID1 ID66 ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 ID9 ID10 ID11 ID12 ID13 ID14 ID15 0 9 10 19 20 29 30 39 40 49 50 59 60 69 70 79 80 89 90 99 100...

Page 6: ...rrect and secure If there is any malfunction of the equipment contact your distributor immediately When transferring the product it is advisable to use the original packaging in which the product left...

Page 7: ...LAYPANEL OPERATION 2009 12 9 3 12 SAVE Only the main menu and the Auto programs submenu can be protected Repower the unit it will back to the main menu 3 11 PASSWORD PASSWORD ON OFF MENU PASSWORD Ente...

Page 8: ...19 28 Each DMX Address may be used as many times as required Any DMX address in the range from 001 to 512 may be used Each DMX address may carry up to 66 separate ID addresses ID should be set in the...

Page 9: ...dr 1 DMX Addr 10 ID Addr 2 DMX Addr 10 ID Addr 3 2009 12 9 7 3 3 STATIC 3 4 AUTO STATIC RED GREN BLUE STRB Select to set the value AUTO Select the target AUTO program and press ENTER Programs AUTO 1 t...

Page 10: ...OPERATION 2009 12 9 9 STATIC AUTO ADDRESS RUN PASSWORD PERSON ID EDIT SETTINGS GREN 000 255 BLUE 000 255 STRB 000 020 RED 000 255 AUTO 1 001 512 SLAVE ON OFF STAGE1 DMX ARC1 ARC1 D AUTO 2 AUTO 3 AUTO...

Reviews: