background image

1.5

    SAFETY WARNING

IMPORTANT

ALWAYS READ THE USER MANUAL BEFORE OPERATION. 

 

PLEASE CONFIRM THAT THE POWER SUPPLY STATED ON THE

    PRODUCT IS THE SAME AS THE MAINS POWER SUPPLY IN YOUR 
    AREA.

 This product must be installed by a qualified professional.
 Always operate the equipment as described in the user manual.
 A minimum distance of 0.5m must be maintained between the 

     equipment and   combustible surface.

 The product must always be placed in a well ventilated area.
 Always make sure that the equipment is installed securely.
 DO NOT stand close to the equipment and stare directly into the LED 

     light  source.

  Always disconnect the power supply before attempting and 

     maintenance.

  Always make sure that the supporting structure is solid and can 

     support the combined weight of the products.

 The earth wire must always be connected to the ground.
 Do not touch the power cables if your hands are wet.

ATTENTION

 This product left the place of manufacture in perfect 

condition.  In order to maintain this condition and for safe 
operation, the user must always follow the instructions and 
safety warnings described in this user manual.

 Avoid shaking or strong impacts to any part of the equipment.
 Make sure that all parts of the equipment are kept clean and 

free of dust.

 Always make sure that the power connections are connected 

correct and    secure.

 If there is any malfunction of the equipment, contact your 

distributor immediately.

 When transferring the product, it is advisable to use the 

original packaging in which the product left the factory.

 Shields, lenses or ultraviolet screens shall be changed if 

they have become damaged to such an extent that their 
effectiveness is impaired.

 The lamp (LED) shall be changed if it has become damaged 

or thermally deformed.

 

1 PRODUCT(GENERAL)

4

2009.12.9  

4.1

    BASIC ADDRESSING

 Connect all of the units in series using standard DMX512 signal 

cable or the IP65 rated cable       provided.

 Set the DMX512 address in the

DMX

menu.

4.2

    CHANNEL ASSIGNMENT

13

4 USING A DMX512 CONTROLLER

 Note: This product have three DMX512 channel configuration: 

STAGE 1

 ,

ARC 1

 and  

ARC 1+D

1

2

 255

3

4

 255

 255

 255

5

 10

11 

 35

36 

 60

61 

 85

86 

 110

111 

 135

136 

 160

161

 185

186 

 210

211 

 215

216 

 220

221 

 225

226 

 230

231 

 235

236 

 240

241 

 245

246 

 250

251 

 255

RED 100% / GREEN UP / BLUE 0%

RED DOWN / GREEN 100% / BLUE 0%

RED 0% / GREEN 100% / BLUE UP

RED 0% / GREEN DOWN / BLUE 100%

RED UP / GREEN 0% / BLUE 100%

RED 100% / GREEN 0% / BLUE DOWN

RED 100% / GREEN UP / BLUE UP

RED DOWN  / GREEN DOWN / BLUE 100%

WHITE 1: 3200K

WHITE 2: 3400K

WHITE 3: 4200K

WHITE 4: 4900K

WHITE 5: 5600K

WHITE 6: 5900K

WHITE 7: 6500K

WHITE 8: 7200K

WHITE 9: 8500K

MARCO

No function

Ch2 will control the  TIME if Ch7 choose custom01-10

DIMMER

Ch3 will control the FADE if Ch7 choose CUSTOM01-10

STAGE 1

BLUE  

CHANNEL   

FUNCTION

VALUE  

GREEN

RED

 

6

 10

11 

 255

Strobe speed

STROBE

No function

4

 

 

USING A DMX512 CONTROLLER

2009.12.9

Summary of Contents for TourSport 21 CM

Page 1: ...T o u r S p o t 2 1 C M Ma n u a l...

Page 2: ...n error 2 Power switch damaged 3 Display board damaged 1 Check all power connections 2 Replace power switch 3 Replace display board LED MODULE on but no control from display 2 Display board damaged 2...

Page 3: ...12 input Independant ID address Stand alone Slave 1 PRODUCT GENERAL 1 1 PRODUCT GENERAL 2009 12 9 4 3 BASIC INSTRUCTIONS FOR DMX512 OPERATION STAGE 1 MASTER DIMMER CH1 controls the intensity of the cu...

Page 4: ...100 240V 50 60Hz 35W 1 PRODUCT GENERAL 2 Environment Temperature 20 40 2009 12 9 9 ID21 ID22 210 211 CHANNEL FUNCTION VALUE 15 4 USING ADMX512 CONTROLLER ID20 200 209 2009 12 9 ID64 ID65 ID66 253 254...

Page 5: ...HANNEL FUNCTION VALUE 14 4 USING ADMX512 CONTROLLER ID ADDRESS ID1 ID66 ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 ID9 ID10 ID11 ID12 ID13 ID14 ID15 0 9 10 19 20 29 30 39 40 49 50 59 60 69 70 79 80 89 90 99 100...

Page 6: ...rrect and secure If there is any malfunction of the equipment contact your distributor immediately When transferring the product it is advisable to use the original packaging in which the product left...

Page 7: ...LAYPANEL OPERATION 2009 12 9 3 12 SAVE Only the main menu and the Auto programs submenu can be protected Repower the unit it will back to the main menu 3 11 PASSWORD PASSWORD ON OFF MENU PASSWORD Ente...

Page 8: ...19 28 Each DMX Address may be used as many times as required Any DMX address in the range from 001 to 512 may be used Each DMX address may carry up to 66 separate ID addresses ID should be set in the...

Page 9: ...dr 1 DMX Addr 10 ID Addr 2 DMX Addr 10 ID Addr 3 2009 12 9 7 3 3 STATIC 3 4 AUTO STATIC RED GREN BLUE STRB Select to set the value AUTO Select the target AUTO program and press ENTER Programs AUTO 1 t...

Page 10: ...OPERATION 2009 12 9 9 STATIC AUTO ADDRESS RUN PASSWORD PERSON ID EDIT SETTINGS GREN 000 255 BLUE 000 255 STRB 000 020 RED 000 255 AUTO 1 001 512 SLAVE ON OFF STAGE1 DMX ARC1 ARC1 D AUTO 2 AUTO 3 AUTO...

Reviews: