ML564 | v3
Page
3
Expo Technologies UK
T: +44 (0) 20 8398 8011
Expo Technologies US
T: +1 (440) 247 5314
Expo Technologies China
T: +86 532 8906 9858
Vortex Cooling Assembly
Relief Valve Unit and Purge Outlet Valve with integral spark arrestor
Maximum:15 mbarg.
Default Setting: 10 mbarg.
Tolerance: -0, +10%
Note: there must be a 2.5 mbarg difference between the intermediate and CLAPS sensor calibration point.
For example: Minimum pressure = 5 mbarg, intermediate pressure = 6.5 mbarg, CLAPS sensor = 9 mbarg.
Purge Time:
User selectable, in 1 minute intervals, up to 99 minutes (tolerance -0, +3
seconds).
Default Setting 99 minutes.
Weight:
26 kg (57lb).
Air Consumption during
Operation:
Approx. 200Nl/min.
Noise during Operation:
Approx. 92dB.
Type:
RLV104/ss/FS, Design number D770RLV.
Bore:
Purge Outlet Valve Ø 104 mm, Relief Valve Ø 75 mm.
Relief Valve Lift-Off Pressure: Minimum:
20 mbarg.
Maximum:
50 mbarg.
Default:
30 mbarg (+0, -20%).
Flow Rate:
Range:
2000, 3000, 4000, 5000, or 6000 NI/min.
Default:
2000 NI/min.
Material:
Housing:
Stainless steel 316L.
Gasket:
Silicone foam.
Spark arrestor:
Stainless steel mesh.
Mounting Method:
Rectangular cut-out and fixing holes as per drawing.
Weight:
7 kg (15.4 lb).