ML564 | v3
Page
1
Expo Technologies UK
T: +44 (0) 20 8398 8011
Expo Technologies US
T: +1 (440) 247 5314
Expo Technologies China
T: +86 532 8906 9858
Section 1: System Specification
5 X LC / ss / ET / OV / H7 / PC / PA
Size
5 = MiniPurge
®
Purge flow rate:
6000 NI/min
Approval / Certification
Sira 01ATEX1295X
0518
II 2(2) G
Ex [pxb] ia IIC T4 Gb
T
amb
-20ºC to +60ºC
IECEx SIR07.0027X
Ex [pxb] ia IIC T4 Gb
T
amb
-20ºC to +60ºC
PC
= Pressurized Control. Automatic
leakage compensation (CLAPS)
OV
= Purge Outlet Valve is
pneumatically operated
Timing Method
ET
= Electronic Timer
MiniPurge
®
Housing
ss
= Stainless Steel 316L
Pressurization Method
LC
= Leakage Compensation
ATEX Certificate:
IECEx Certificate:
PA
= Power and Alarm Switches.
Integral /PA Terminal Box
For limitations and
conditions of use refer to
the applicable certificates.
High Temperature
=
Tamb: -20ºC to +60ºC
Purge air Temp: max 70ºC
INMETRO CERTIFICATE:
TÜV 12.1462X
Ex [pxb] ia IIC T4 Gb
T
amb
-20ºC to +60ºC