Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
50
Appendix A: Power Consumption
eTOP-MON 1200T/1205T/1500T/1700T/1900T User Manual
A
PPENDIX
A: P
OWER
C
ONSUMPTION
Purpose
The purpose of the power consumption test is verified the power
dissipation of the system and the load of the power supply.
Test Equipment
PROVA CM-07 AC/DC CLAMP METER
Desktop PC
Device Under Test
DUT: Sys #1
Test Procedure
1. Power up the DUT and then switch on the desktop PC connecting to it.
2. Measure the power consumption and record it.
3. Enter the standby mode (Turn off display).
4. Measure the power consumption and record it.
eTOP-MON 1200T
+12V
+24V
Full-Loading Mode
0.73A
0.39A
Total
8.76W
9.36W
Standby Mode
0.05A
0.06A
Total
0.6W
1.44W
eTOP-MON 1205T
+12V
+24V
Full-Loading Mode
0.75A
0.39A
Total
9W
9.36W
Standby Mode
0.05A
0.05A
Total
0.6W
1.2W
eTOP-MON 1500T
+12V
+24V
Full-Loading Mode
0.97A
0.5A
Total
11.64W
12W
Standby Mode
0.04A
0.05A
Total
0.48W
1.2W
eTOP-MON 1700T
+12V
+24V
Full-Loading Mode
2.6A
1.21A
Total
31.2W
29.04W
Standby Mode
0.05A
0.05A
Total
0.6W
1.2W
eTOP-MON 1900T
+12V
+24V
Full-Loading Mode
1.54A
0.77A
Total
18.48W
18.48W
Standby Mode
0.05A
0.05A
Total
0.6W
1.2W