20
| UK
Your energy.
Optimized.
Maintenance and troubleshooting
The motor has special ball bearings that are sealed, lifetime lubricated and maintenance-free. If replace-
ment of the bearings is required, this should be carried out by qualified professionals.
The run capacitor is considered a wear part and will need to be replaced depending on usage.
Gas appliances should be checked for safety once a year by a installer registered in the Gas Safe Register.
Details of local installers can be obtained by accessing the website at
www.gassaferegister.co.uk
Inspection
It is recommended that the fan and its connections should be inspected once a year at the same time as the
annual maintenance of the appliance.
•
Remove all soot deposits on the impeller and the sensors.
•
On inspection, care should be taken that the flow measuring system is not damaged.
In open position, the hinged chimney fan provides easy access for service and maintenance.
WARNING! Do not open the motor housing unless
the power to the chimney fan has been disconnected!
CAUTION! Do not overfire the fireplace/stove. Small deposits of
creosote could be ignited and start a small chimney fire which could
cause the chimney flue to reach a dangerously high temperature.
ATTENTION! Turn the fan off at the isolation switch before any maintenance work commences.