This example shows how to connect a voltage signal (18-230 V AC/DC) to EBC24 to start/stop the chimney fan.
• Connect the supply to terminals 1-3.
• Connecting the boiler:
• Connect the burner start signal (L) to terminal 12.
• Connect the neutral wire to terminal 13.
• The start signal for the burner is sent from terminal 15.
• Loop terminals 12 and 14.
• Connect the chimney fan to terminals 4-6.
• Connect the pressure transducer (XTP) to terminals 22-24 with a shielded cable, and connect the dis-
play to terminal 6
3120073-UK EBC24
20
• Pressure control