Maintenance
Important:
In order to prevent damage to the
battery, use an automatic 12 volt smart charger
approved for use with AGM type batteries with an
output of 3.5 amps or less. Exmark recommends
the use of battery charger P/N 135-7024. Make
sure the negative battery cable is disconnected
before charging and that the charger is set to
the correct mode for 12V AGM batteries. This is
especially important on Kohler EFI (Electronic
Fuel Injection) models. Failure to do so may
damage the ECU (Electronic Control Unit).
Important:
For Kohler EFI Models: Disconnect
the battery and unplug the harness from the
engine ECU before performing any welding on
the equipment.
Recommended Jump
Starting Procedure
Service Interval: As required
1.
Check the weak battery for terminal corrosion
(white, green, or blue “snow”), it must be cleaned
off prior to jump starting. Clean and tighten
connections as necessary.
CAUTION
Corrosion or loose connections can cause
unwanted electrical voltage spikes at anytime
during the jump starting procedure.
Do Not attempt to jump start with loose or
corroded battery terminals or damage to the
engine or EFI may occur.
DANGER
Jump starting a weak battery that is cracked,
frozen, has low electrolyte level, or an
open/shorted battery cell, can cause an
explosion resulting in serious personal injury.
Do Not jump start a weak battery if these
conditions exist.
2.
Make sure the booster is a good and fully charged
lead acid battery at 12.6 volts or greater. Use
properly sized jumper cables (4 to 6 AWG) with
short lengths to reduce voltage drop between
systems. Make sure the cables are color coded or
labeled for the correct polarity.
CAUTION
Connecting the jumper cables incorrectly
(wrong polarity) can immediately damage the
electrical and/or EFI system.
Be certain of battery terminal polarity and
jumper cable polarity when hooking up
batteries.
Note:
The following instructions are adapted
from the SAE J1494 Rev. Dec. 2001 – Battery
Booster Cables – Surface Vehicle Recommended
Practice (SAE – Society of Automotive
Engineers).
WARNING
Batteries contain acid and produce explosive
gases.
•
Shield the eyes and face from the batteries
at all times.
•
Do Not lean over the batteries.
Note:
Be sure the vent caps are tight and level.
Place a damp cloth, if available, over any vent
caps on both batteries. Be sure the vehicles do
not touch and that both electrical systems are
off and at the same rated system voltage. These
instructions are for negative ground systems only.
3.
Connect the positive (+) cable to the positive (+)
terminal of the discharged battery that is wired to
the starter or solenoid as shown in Figure 15.
29
Summary of Contents for STARIS S Series
Page 1: ...STARIS S SERIES For Serial Nos 408 644 346 Higher Part No 4505 317 Rev A ...
Page 50: ...Schematics Schematics Electrical Schematic Kawasaki g303795 50 ...
Page 51: ...Schematics Electrical Schematic Kohler EFI g303794 51 ...
Page 52: ...Schematics Hydraulic Diagram g304191 52 ...
Page 54: ...Service Record Date Description of Work Done Service Done By 54 ...
Page 55: ...55 ...