g030223
Figure 30
1.
Hydraulic trans oil
3.
Y (yes)
2.
Use Exmark Premium Oil
service interval?
4.
N (no)
5.3.3 Access Historical Error Log
The historical error log displays errors that are no
longer active. The log keeps a running count of the
number of times the error has occurred during the life
of the machine and the non-resettable engine hour at
which the last occurred. The log displays the errors
starting with the most recent occurrence.
g030224
Figure 31
1.
Historical error
3.
Number of times error
occurred during life of
machine (e.g. 3X)
2.
Current error (e.g. Low oil
pressure)
4.
Hour occurred
5.3.4 Activate/Deactivate The Alarm Output
For Individual Errors
The alarms screen allows users to activate and
deactivate the audible alarm for individual errors.
Pressing the enter button brings the user to screens
that allows the user to activate or deactivate the
audible alarm for individual errors.
Note:
Not all audible alarms can be deactivated.
g030225
Figure 32
1.
Alarms
3.
Audible alert
2.
Activate/Deactivate
4.
Enter/Return
The highlighted error name indicates that the audible
alarm is active. Pressing enter modifies the status of
the audible alarm to ON or OFF.
g038366
Figure 33
1.
Alarms
4.
Toggle
2.
Clutch overcurrent
5.
Enter/Return
3.
Fuel low
The audible warning for the following errors can be
deactivated:
•
Service Engine Oil
•
Service Transmission Oil
•
Fuel Low
•
Clutch Overcurrent
•
Clutch Reset Required
•
Engine Error Codes
•
System Overvoltage>16VDC
•
System Undervoltage<9VDC
•
System Voltage Low
5.3.5 Adjust the Engine Speed Set Points
The screen allows the user to adjust the engine
speed at the
Max, Efficient,
and
Low
set points for
both transport (clutch disengaged) and mow (clutch
engaged) modes in 50 RPM increments.
14