Curtiss-Wright | Tritex II DC Rev. J PN49220 2/8/2016
42
Analog Input
An analog input is provided for use as a position, velocity or current
command.
Differential input range is -10 V to +10 V. Input range on Analog IN+ is
-15 V to +15 V with respect to I/O Common. Input range of Analog IN- is
-15 V to +12 V with respect to I/O Common. Due to voltage drop in the
wiring to BUS-, the analog signal must be wired differentially with a
return wire to the analog signal source.
(See software section for configuration of the analog input and analog
positioning parameters.)
Analog input wiring from voltage or current control external controller
Note: Analog input reference from an external controller must be
referenced to single point ground to prevent damage to the analog input
circuit.
Analog Input Specifications
Description
Specification
Voltage Input Range
-10 V to +10 V
Input impedance
100 k
Ω
Input resolution
13 bits over full -10 V to +10 V range
Update rate
0.5 ms
Summary of Contents for Tritex II DC Series
Page 8: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 8...
Page 9: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 9...
Page 10: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 10 EU Declaration of Conformity for CE Mark...
Page 19: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 19 Dimensions...
Page 20: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 20...
Page 21: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 21...
Page 22: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 22...
Page 23: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 23...
Page 53: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 53 Cable Shield Grounding Example...
Page 62: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 62 ACCESSORIES Cables TTIOC xxx I O Cable...
Page 63: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 63 TTIPC xxx Power Cable...
Page 64: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 64 TTICO xxx Communications Cable...