3002367-2008-06-01.fm
GB - Product information
41/56
Examples
Accessing the set-up menu
To access this menu, press the OK button (B) (drawing 10) and hold it down for at
least 3 seconds.
To exit the menu, press the ON/OFF button (D).
Use the arrow buttons (A and C) to scroll back and forth between the various
menu items.
Changing the set-up of a menu item (drawing 10)
For additional information about the various menu items, refer to the section entitled
“Overview of menu structure”.
6.3 Control panel settings
Example 1
Example 2
Changing the language for operational guide
Connect temperature sensor
Action
Display
Action
Display
Press the OK button (B)
for 3 sec.
1 Exit <
Press the OK button (B)
for 3 sec.
1 Exit <
Press the right arrow
button (A) five times
6 SERVICE >
Press the right arrow
button (A) once
2 Sensor >
Press the OK button (B)
60 Exit <
Press the OK button (B)
20 Exit <
Press the right arrow
button (A) three times
63 Language>
Press the right arrow
button (A) once
21 Sensor
mode >
Press the OK button (B)
Language
<-English->
Press the OK button (B)
Set Mode
<-Off->
Press the right arrow
button (A) two times
Language
<-Norsk->
Press an arrow button
(A or C)
Set Mode
<-On->
Press the OK button (B)
63 Language>
Press the OK button (B)
21 Sensor
mode >
Press the ON/OFF button
(D)
IN OPERATION
40% *22°
Press the ON/OFF
button (D)
IN OPERATION
40% *22°
6.4 Recommended set-up
RECOMMENDED PARAMETER SET-UP
Parameter
Wood-burning stove/
Steel chimney
Wood-burning stove
Uninsulated brick
chimney
Open fireplace
START TEMP
40°C
25°C
25°C
STOP TEMP
35°C
20°C
20°C