R2000 Radiometer 

UV/VISIBLE RADIOMETER 

250 – 1000 nm 

 
 

 
 

 
 
 

USER’S GUIDE 

 

 
 

 
 

Printed in Canada 

  035-00243 Rev. 4 

Summary of Contents for OmniCure R2000

Page 1: ...R2000 Radiometer UV VISIBLE RADIOMETER 250 1000 nm USER S GUIDE Printed in Canada 035 00243 Rev 4...

Page 2: ...alent Windows 98 2000 or XP 32 Mb RAM 10 Mb for Software Installation 20 Mb for Data Storage SVGA video 800x600 resolution One available RS 232 Port Trademarks OmniCure is a trademark of EXFO Photonic...

Page 3: ...DE 13 4 9 MEASURING IN ABSOLUTE MODE 14 4 10 CONNECTING EXTERNAL RADIOMETER DEVICES 14 4 11 STORING DATA 17 4 12 INTERFACING WITH OMNICURE UV CURING SYSTEMS 18 4 13 CALIBRATING OMNICURE UV CURING SYST...

Page 4: ...ICATIONS 39 7 1 OPTICAL 39 7 2 ELECTRICAL 40 7 3 MECHANICAL 40 7 4 RS 232 COM PORT CONFIGURATION 40 7 5 ENVIRONMENTAL CONDITIONS 41 7 6 REGULATORY COMPLIANCE SAFETY 41 7 7 WEEE DIRECTIVE 2002 96 EU 44...

Page 5: ...have come to expect from EXFO Life Sciences Industrial Division At the heart of the R2000 Radiometer are two proprietary systems a non imaging optical interface that virtually eliminates measurement...

Page 6: ...al interface collects light over a large area Eliminates beam intensity and radiance dependence Auto ranging Maintains precision over full range Real time Mode Allows for tracking of a varying signal...

Page 7: ...and makes operation easier IR Link Provides wireless connection with OmniCure compatible Series of UV Curing Systems RS 232 connection to OmniCure Series of UV Curing Systems Allows calibration and se...

Page 8: ...elf with the R2000 Radiometer Thumbscrew Optical Input Port Light Guide Adapter IR Window Remote Input Connector Note For connection of optional cure site cure ring radiometer only RS 232 Connector Ru...

Page 9: ...the output dimension of the light guide depending on the colour of the light guide adapter inserted Thumbscrew Used to secure the light guide adapter to the light guide IR Window Located on the top o...

Page 10: ...ue OmniCure CAL Used to calibrate and set up compatible OmniCure UV Curing Systems to a specified irradiance POWER IRRAD Each press of this button toggles between Power or Irradiance measurements EXTE...

Page 11: ...er boot is optional and can be removed when not desired When the boot is utilized the RS 232 connector and Remote Input connector are accessible by lifting flap on the right side of the boot Acronyms...

Page 12: ...The R2000 Radiometer will automatically turn OFF after 1 minute if the unit does not detect any optical input RS232 communication or keypad activity Note The R2000 Radiometer remains in the same meas...

Page 13: ...EEN One other size is available 2mm GOLD Note If the R2000 Radiometer is on when the adapter is installed the display will flash the diameter of the light guide adapter for 3 sec Insert the light guid...

Page 14: ...ustom light guide adapter is required Contact EXFO Life Sciences Industrial Division for further details Refer to Section 9 Note The diameter of the light guide must be entered in the PC software befo...

Page 15: ...he R2000 Radiometer automatically detects the size of the light guide that is inserted calculates the irradiance and displays the measurement 4 7 Measuring Power When measuring power the display will...

Page 16: ...initial reference measurement A reading of 200 indicates that the current measurement is double of the initial reference Inserting a light guide from a different source will provide a measurement tha...

Page 17: ...of the EXTERNAL keypad button will increment to the next external device before returning back to internal mode This is indicated on the display when the EXT icon is no longer illuminated The measurem...

Page 18: ...Page 16 of 50 The following illustrates the use of the EXTERNAL feature with four external radiometer devices Sensor 4 R2000 Dongle Sensor 1 Sensor 3 Sensor 2 Connection via Remote Input Jack...

Page 19: ...E button is pressed the display shows the MEM icon and a number starting at 1 that corresponds to the number of stored readings The number will increment each time STORE is pressed and the measurement...

Page 20: ...r communication with compatible OmniCure curing systems When connected the R2000 Radiometer is able to calibrate the OmniCure SERIES 2000 UV Curing System and set the irradiance to a specific level To...

Page 21: ...and the display will indicate the current set point When the keypad is released a series of dashes will illuminate across the display which indicates that the set point is being communicated to the O...

Page 22: ...it color 16 bit color or better recommended Available RS 232 COM port Operating System Requirements Microsoft Windows 95 98 NT 2000 ME or XP The R2000 Radiometer comes complete with a CD that includes...

Page 23: ...title bar displaying R2000 Control Panel will appear Click on Connect at the top of the screen The R2000 Control Panel will open when there is a successful connection This should take no more than a...

Page 24: ...message Click OK Select from the File pull down menu COM Ports Ensure that the applicable COM port is checked and cable is connected to corresponding plug Try connecting again Note This error may als...

Page 25: ...ctive areas of the Control Panel Some data is user defined such as Set Point Relative Reference Custom Adapter Diameter LCD Contrast Note When data is entered into a user defined field the background...

Page 26: ...fined fields Power Displays real time data as it pertains to readings being taken from the R2000 Radiometer This displays as either mW or W Irradiance Displays real time data as it pertains to reading...

Page 27: ...er being detected from the R2000 Radiometer The Misc frame displays a combination of real time data as it pertains to readings being taken from the R2000 Radiometer as well as user defined fields S N...

Page 28: ...e RTC date time stamp is not the same as the PC clock use the Set R2000 Radiometer Clock function under the File menu to synchronize Status The Status frame indicates the applicable status modes of th...

Page 29: ...x will be checked when Internal is highlighted in the Source frame This indicates that optical input is being received from the optical port on the R2000 Radiometer S N Included in Data Logs When chec...

Page 30: ...er from the PC select desired menu functions located across the top of the R2000 Control Panel Display Select the Display menu and then select the desired mode of Power Irradiance Absolute or Relative...

Page 31: ...onality from the front keypad of the R2000 Radiometer Select from the available list in the pull down menu The selections that are checked are indicated in the Lockout frame If a box is checked this m...

Page 32: ...e installed in the R2000 Radiometer Data Log Select the Data Log menu option and select the desired option from the pull down list Select Clear to clear any existing data that may be resident in the d...

Page 33: ...Select Log Readings During OMNICURE CAL to log each calibration point into the Data Log during a calibration cycle with a compatible OmniCure UV Curing System The following is a sample screen shot of...

Page 34: ...Page 32 of 50 Power Down Select this menu option to power down the R2000 Radiometer...

Page 35: ...cuments CAUTION Never look into the light emitting end of a light guide The light could severely damage the cornea and retina of the eye if the light is observed directly Eye shielding must be used at...

Page 36: ...t to be discarded Return to the nearest authorized EXFO service center for disposal re cycling Lithium batteries must have terminals taped with non conductive material prior to returning for disposal...

Page 37: ...this occurs it is recommended that the R2000 Radiometer be serviced See Section 9 6 2 Display Indicates BAT Message If the BAT icon appears on the lower left side of the display it indicates that the...

Page 38: ...back into the rubber boot if desired Used batteries are not to be discarded Return to the nearest authorized EXFO service center for disposal re cycling Use appropriate safety measures found in Secti...

Page 39: ...d it indicates that the R2000 Radiometer was unable to communicate with an external adapter 6 5 Display Indicates LG Message The LG message as illustrated below will appear when the R2000 Radiometer i...

Page 40: ...r be cleaned or replaced 6 7 Display Indicates Loc Message If the Loc message appears on the display when a keypad button is pressed it indicates that the function has been locked out 6 8 Display Indi...

Page 41: ...W 15W Irradiance 2mW cm2 475W cm2 Resolution Power Range 0 007 1 999mW 0 01mW 2 00 19 99mW 0 01mW 20 199 9mW 0 1mW 200 1999mW 1mW 2 00 19 99W 10mW Accuracy 5 typical 10 maximum Auto ranging Power 1 99...

Page 42: ...t 6 Pin Mini DIN connector 7 3 Mechanical Dimensions 6 5 x 3 9 x 1 7 inches L x W x H Without rubber boot 7 5 x 4 4 x 2 inches L x W x H With rubber boot Weight 700 g With rubber boot 7 4 RS 232 Commu...

Page 43: ...Humidity 10 to 100 non condensing Atmospheric Pressure 500 to 1060 hPa 7 6 Regulatory Compliance Safety The R2000 Radiometer has been designed to meet the requirements of the following standards IEC...

Page 44: ...tified to meet the Class 1 eye safety specifications of IEC 825 1 EN 60825 1 Electromagnetic Compatibility EN 61326 1 2001 A1 A2 Electromagnetic Compatibility Immunity Testing Measurement Control and...

Page 45: ...Page 43 of 50 China RoHS The following table contains substance information for the Omnicure R2000 as required by China RoHS regulations Pb Hg Cd Cr6 PBB PBDE x x x SJ T11363 2006 x SJ T11363 2006...

Page 46: ...for its production It may contain hazardous substances that could impact health and the environment In order to avoid the dissemination of those substances in our environment and to diminish the pres...

Page 47: ...wever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by...

Page 48: ...s can recommend light delivery solutions for a range of manufacturing illumination and biomedical applications We also welcome custom requests for unique light delivery requirements 3 6V Lithium Batte...

Page 49: ...f situations Optical accessories include the Proximity Measurement Adapter and the optional Lamp Output Adapter These adapters expand the range of measurement geometries that can be accommodated 5mm P...

Page 50: ...material or workmanship must be reported to an authorized EXFO Service Centre within 30 days from the original date of receipt EXFO will repair or replace these reported defects free of charge for a p...

Page 51: ...CANADA Tel 1 905 821 2600 Toll 1 800 668 8752 USA and Canada Fax 1 905 821 2055 www exfo uv com omnicure exfo com Service or calibration information may be obtained by contacting your nearest OmniCur...

Page 52: ...ologies Pte Ltd 10 Science Park Road 01 06 The Alpha Singapore Science Park Singapore 117684 P 65 6779 0900 F 65 6779 0800 info cadence tech com sg San Ei Tech Ltd 1 15 7 Chome Kashiwa Kashiwa Shi Chi...

Page 53: ......