background image

16

12V DC
INPUT

    RS485
      + ‘

A’

ORANGE

RS485
    - ‘B’
YELLOW

RS485  INPUT  ON
DVR

PSU

CA

T5 D

at

a cable

RG

59 V

ideo C

able

Pow

er Cable

12V DC

Summary of Contents for PTZ200

Page 1: ...Installation and Operation Manual Economic PT Dome 12vDC Models covered PTZ200 Version 1 For updates to these instructions visit www excelPTZ com the excelPTZ range...

Page 2: ...Powering the domes 13 RS485 connection Connecting the Keypad or DVR to the Dome 14 Connecting the video out of the dome 15 Setting the PTZ dip switches 17 Setting up a unique address in a dome 18 Set...

Page 3: ...high voltage equipment such as mains cables and especially fluorescent lights Using an anti surge protection device is recommended to prevent damage to the domes from lightning and mains surges Damag...

Page 4: ...our option Description of Functions 1 Integrated Multi Protocol Decoder The integrated multifunctional decoder can communicate with 5 different protocols The baud rate can be independently set allowin...

Page 5: ...the comfort of your own premises Overview introduction to fitting PTZ equipment Generally speaking PTZ Domes requires four things 1 They require a power supply and a cable to supply this power to the...

Page 6: ...idering using baluns please note DVR s tend to require very good video signals to function correctly and passive baluns can loose some signal strength over the 50 metre mark so try to restrict the use...

Page 7: ...ards RS485 is a half duplex data transmission type with characteristic impedance of 120 The maximum load capacity is 32 units domes keyboards and DVRs 2 Transmission distances of RS485 Signals using C...

Page 8: ...eliability so that the domes function as expected A common mistake installer s make is not making sure the 120 resistor is switched ON in the LAST dome Also installers often select the resistor to ON...

Page 9: ...is connected and when the jumper is set between positions 2 and 3 the resistor is not connected JP1 1 2 2 3 120R O N O FF O N DI P 1 2 3 4 5 6 7 8 9 10 O N DI P 1 2 3 4 5 6 JP1 1 2 2 3 120R O N O FF J...

Page 10: ...dome s movements are tiny signals that can get corrupted for many reasons Poor cable quality not using a PAIR of cores from a CAT5 but using one core from TWO separate pairs running the CAT5 cable ne...

Page 11: ...ne dome on each spur from the PTZ750 but up to 4 domes is generally acceptable The following diagram shows a typical use of the PTZ750 RS485 distributor In the following example and diagram domes 1 4...

Page 12: ...a good idea what your options are Below is a general schematic diagram showing you some of these options PTZ DOME 12V DC CAT 5 CAT5 Carries Video Control Data CCT CAMERA Video Power TRADITIONAL CAMER...

Page 13: ...a 2 1mm mini jack socket connected Connect a suitable 12V D C power supply with a mini jack plug The BNC connector is the VIDEO OUT from the camera and goes to the monitor or VIDEO IN of a DVR camera...

Page 14: ...have done this it is just a job of extending the cables and physically installing the domes on site You must obviously take note of the RS485 wiring techniques mentioned at the beginning of these ins...

Page 15: ...ld always take your test monitor to your PTZ dome and check the picture quality on its own short BNC lead If you re testing the equipment on a workbench you now have a one dome system You can use a ke...

Page 16: ...16 12V DC INPUT RS485 A ORANGE RS485 B YELLOW RS485 INPUT ON DVR PSU CAT5 Data cable RG59 Video Cable Power Cable 12V DC...

Page 17: ...then the default address of 1 is okay and you have no reason to change the dome from this With multiple dome sites you need to set up each dome address separately This is accomplished by setting the S...

Page 18: ...IP 2 DIP 3 DIP 4 DIP 5 DIP 6 DIP 7 DIP 8 DIP 9 DIP 10 1 ON OFF OFF OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF...

Page 19: ...1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 SAMSUNG ON OFF OFF OFF OFF ON B01 ON OFF OFF OFF OFF ON PELCO D ON ON OFF OFF OFF OFF PELCO P 4800 ON OFF PELCO P 9600 OFF OFF ON OFF OFF ON ALEC OFF ON ON ON OFF ON Ta...

Page 20: ...sed to select the baud rate of communication and a maximum of 4 different baud rates can be selected If the controller adopts a non standard baud rate you can adjust it to be identical with that of th...

Page 21: ...rotocol protocol D or P The current camera address each P T device requires a unique address 1 32 The current baud rate To set up the keyboard to the correct settings for this dome do the following TI...

Page 22: ...point is 7 5 per second In the dome some preset numbers are reserved for special functions these are listed as follows What you press at the keyboard PRESET No Special function Press XX then CALL XX...

Page 23: ...limits of its scan To start an Auto Scan press 51 CALL TIP To stop the scan just move the joystick slightly Patrols Tours How to set them up and use them A patrol tour is simply a collection of at lea...

Page 24: ...that the preset has been deleted For example to delete preset 1 press 01 PRESET holding the preset button for 3 seconds Obviously if you wish to overwrite a preset with a new location simply aim the c...

Page 25: ...lation Instructions Dimensions 130 60 100 R67 5 5 Dimension of shell Ceiling mount board Installation a Ceiling mount PO W ER PO W ER D C12V O range O range R S485 Yel l ow Yel l ow R S485 VID EO VID...

Page 26: ...26 b Suspended installation 300 7 Fixed bracket Orientation aperture 130 86 40 Suspended installation board a Wall mount 3 Wall mount board...

Page 27: ...his is used for installing the dome cable housing and hiding the connection cable 2 Take out the two fixed Allen screws using the specialAllen key t ake of f Screw on 3 Due to the two rubber waterproo...

Page 28: ...ud and push the unit into the metal shell and refit the screws 6 Hide the cable in the ceiling aperture and fix the dome to the ceiling 7 Ensure the video power and data cables are connected as per in...

Page 29: ...2 Remove the ceiling installation board and replace with the wall installation board feeding the connection cable across the front on the bracket through the cable aperture 3 Fit the dome to the wall...

Page 30: ...30 5 Correctly fit the connection cable...

Page 31: ...Specifications Waterproof standard IP66 Horizontal Resolution 380 TVL 470 TVL enhanced Signal Noise ratio 52db min 60db TYP AGC OFF Digital zoom x2 Optional Electronic Shutter 1 50 1 120000sec Lowest...

Reviews: