26
can’t display CID correctly and you know the CID mode, you can use 1812#
or 1813# to set CID mode compulsively.
3.21 Ext. groups function setting
3.21.1 Assign the Exts. groups number
The extensions can be set to 2 groups, each group is from 01 to 08
and have a programmed number. Setting methods is as below(similar to
flexible code).
Format:
9 9 0 abcd #
Description:
to set the first groups’ number and enable the first Exts
Group
1
、
The length of Exts groups number should be same to the first
extension number, and the Exts group numbers should be
different to the other extensions number.
2
、
Default setting is not setting.
Format:
9 9 1 abcd #
Description:
to set the second groups’ number and enable the second
Exts Group.
Default setting is is not setting.
3.21.2 Join the Exts. groups members
Format:
3 9 0 #
Description:
to delete all extension members in the first Exts group.
Format:
3 9 0 N
1
N
2
… N
R
* N
S
.. N
T
#
Explanation:
N
1
、
N
2
、
N
R
、
N
S
、
N
T
: the Ext. series No , = 1-8 (not 01-08)
means ext 601-608
Description:
In the first Exts group join in Ext. N
1
、
No.N Ext.
2
、
No.N
Ext.
T
、。。。
and from Ext. N
R
to No.N Ext.
S
in sequence members.
Example:
to join Ext.601
、
Ext.602
、
and Ext.605 …to Ext.608(include
Ext.608) in sequence to be the first Exts.group member,then input 290 1 2
5 * 8 #.
After setting,when you dial the first Exts group number (such as 20 refer
3.21.1 ),the Ext.601 Ext.602
、
Ext.605 and Ext.608 will ringing at the same
time.
Format:
3 9 1 #
Description:
to delete all extension members in the second Exts group.
Format:
3 9 1 N
1
N
2
… N
R
* N
S
.. N
T
#
Description:
In the second Exts group join in Ext. N
1
、
No.N Ext.
2
、
No.N
Ext.
T
、。。。
and from Ext. N
R
to No.N Ext.
S
in sequence members.
1
、
The first Exts group members is join by the extensions from 601-604
in default setting.
2
、
The first Exts group members is join by the extensions from 605-608
in default setting.
Summary of Contents for MK-208