5-3 Analogue Current / Voltage Output Interface (OP-03)
Location
A B C
A. Terminal (4 way)
1 : 0 ~ 20mA current output, positive
2 : 0 ~ 10V voltage output, positive
3 : Current / voltage signal, negative
4 : Ground / 0V
B. SPAN adjustment
Current / voltage Span adjustment to increase value turn clockwise, decrease value
turn anticlockwise.
C. ZERO adjustment
Current / voltage Zero adjustment to increase value turn clockwise, decrease value
turn anticlockwise.
Analogue output interface specification
Resolution : 16
bits
Current output : 0 ~ 20mA ( 0 ~ 550
Ω
load)
Voltage output : 0 ~ 10V
CAL
2
1
3
4
5
10
6
7
8
9
11
12
13
2
1
2. V (+)
1. A (+)
-
SPAN
3. Com. (-)
4
3
+
ZERO
+
-
4. FG
ON