46
04011010
EXCELL PRECISION CO., LTD
ZSME400000002
Function setting
Press the key
Input desired
Parameter code
Press the key
Display shows the existing
parameter code. Input
new code as need.
Press the key
Continue to another function setting
or press key to escape
Setting value
Item Function
Parameter
Description
Default
0 As
display
1 Gross
bCd- 01
Data type
2 Net
0
0 Transmit
continuous
1 Auto
transmit
bCd- 02
Transmit mode
2 Manual
transmit
0
0
Positive logic action
bCd- 03
Output Logic
1
Negative logic action
0
0
Positive logic action
bCd- 04
Data ready
Signal logic
1
Negative logic action
0
0 FFFFFF
bCd- 05
OL output code
1 999999
0
0 BCD
Code
bCd- 06
Data code
1 Hex.
Code
0
⇒
Increment flashing digit
⇒
Decrement flashing digit
⇒
Move flashing point left
⇒
Move flashing point right
⇒
Store data in memory
⇒
Exit
/