EXCELL PRECISION CO., LTD
ZSME400000002
3. COMMAND FORMAT C
Host
C Data
<CR>< LF>
Slave
C Data
<CR>< LF>
Write weight compared value WS
□□
XXXXXX
XXXXXX : value (6 bytes)
□□
: setting items
FW
Write target item of unload value
S1 Write
SP1
S2 Write
SP2
S3 Write
SP3
UD Write Under
LO Write LO
ZB Write Zero Band
HI
Write HI
PR Write Peak value
OV Write Over
BC Write SQ14
PT Set OUT
Note
:
WSPTxxxxxx (input 0~255 decimal system) converts to BIT value which
indicates OUT (1-8) is ON, and the rest of numbers are OFF.
Ex:
Inputting WSPT000010 means the BIT value is 00001010 (OUT 2, 4 = ON) (OUT
1, 3, 5, 6, 7, 8 are OFF).
Error messages
E1: Format command fault
E2: Setting parameters over range
E3: Command not recognised
Indicator poling address
If the indicator has an address configured in RS1 (2) – 07, it will only
respond to messages prefixed with its address.
For example:
The indicator poling address is set to 02; it would send the weight value
only if it received the command:
@02RW
<
CR
><
LF
>