![Excelitas Technologies AC2110-365 Installation Reference Manual Download Page 7](http://html1.mh-extra.com/html/excelitas-technologies/ac2110-365/ac2110-365_installation-reference-manual_2449434007.webp)
OmniCure® AC2 Series
UV Curing Solutions
http://www.excelitas.com/omnicure
Excelitas Canada Inc. 2015
All rights reserved
035-xxxxxR, rev.1
2
035-00589R Rev5
2
Safety Precautions/ User Warnings
2.1
Glossary of Symbols
Caution risk of danger – consult accompanying documents.
Risk Group
WARNING: UV emitted from this product. Avoid eye and skin exposure to unshielded product.
WARNING: Possibly hazardous optical radiation emitted from this product. Do not stare into operating lamp.
Input/ Output Signals
Input Signal
Caution, Hot Surface
Protective Conductor Terminal
Earth (Ground) Terminal
CAUTION, Risk of Electrical Shock
2.2
Safety Precautions
This series of cautions and warnings relate to the installation, operation and maintenance of the OmniCure® AC-
System. They are also presented throughout this Installation/Reference Guide as applicable.
WARNING
Do not stare directly at the light emitted from the LED array. This may be harmful, resulting in eye injury.
Always use UV protective eyewear as indicated below. Additionally, protect any exposed skin with appropriate
clothing or shielding as required.
Warning UV protective eyewear must meet the following recommended optical specifications:
Spectral range; 350-440nm
Optical Density ≥ 6
Warning Should the OmniCure® AC- System be used in a manner not specified by Excelitas Technologies, the
protection provided by the equipment may be impaired.
The UV LED Head operation can be affected if handled incorrectly. Never touch the protective lens cover
assembly of the UV LED Head. The presence of skin oils may result in a decrease in system performance.