Exalux LEDMASTER STUDIO 1 User Manual Download Page 7

13 - DIMMING CURVES

14 - TRIGGER

The trigger input is a dry-contact between the two pins of the terminal block connector. 

Do 

not apply any voltage on this input

. Dry contact trigger input should be used with passive 

switches, in respect with the common GND equipotential reference.

   - In DMX & CRMX mode, when the contact is closed, the DMX/CRMX commands are 

     by-passed and the value set on the 16-position rotary switch is applied to the output. 
   - In manual mode, when the contact is closed, the output is turn off (black out).

15 -  INSTALLATION & CABLING

LEDMASTER STUDIO 1 enclosure is designed to be mounted onto a standard DIN rail 35mm 

width (EN 60715), but wall mounted is another option. Use the embedded plastic hook to 
attach or detach from the rail. This device is delivered with all required terminal block plugs.

16 - FACTORY RESET

To factory reset the device, press and hold the RESET push button during 10secs. The device 

will flash memory to default factory settings and restart.

Note: Hardware settings on the DIP switch (SETTINGS) and rotary switches (DMX ADDRESS, 
MANUAL DIMMING) will be automatically restored.

17 - DRAWINGS

64.90mm

108mm

91mm

98mm

170.65mm

142.30mm

Note 1: the CUSTOM dimming curve 

has been optimized for 18,5W 12V 

AR111 spot at 32kHz

Note 2:  dimming curves correspond 

to the 8 bits mode (0-255), but 16 bits 

mode is very similar

Summary of Contents for LEDMASTER STUDIO 1

Page 1: ...er optional This dimmer is integrated in a standard DIN rail enclosure with 5 08mm pluggable terminal blocks for quick and easy set up The LEDMASTER STUDIO 1 is available in several versions which can...

Page 2: ...t only for AC versions DC Input only for DC versions DMX In Out Power LED indicator red Reset Unlink switch 2 4GHz SMA mount antenna only for CRMX versions 3x CRMX signal level LED indicators green on...

Page 3: ...not exceed 7 5A per contact on terminal blocks and cables In case of a load higher than 7 5A it is imperative to distribute the power on the four input and output pins 7 GENERAL SPECIFICATIONS AC Pow...

Page 4: ...viour in case of DMX stream interruption lost signal DMX cable issue controller Off 00 Hold Hold the current last valid DMX values 01 Black Forced blackout turn off output 10 Man dimming Apply the bri...

Page 5: ...DIP switch settings do not necessarily correspond to the current operating mode The RDM features can be used on both wired DMX and wireless CRMX RDM manufacturer identifier 0084h RDM labels LEDMASTER...

Page 6: ...s indicator turns off You can also unlink all linked receivers from the transmitter Signal level indicators Blinking no signal 1 LED poor reception 2 LEDs correct reception 3 LEDs excellent reception...

Page 7: ...is designed to be mounted onto a standard DIN rail 35mm width EN 60715 but wall mounted is another option Use the embedded plastic hook to attach or detach from the rail This device is delivered with...

Page 8: ...g it In case of non compliance devices may be damaged and the user may be injured Cable The section of power cables on AC and DC input output should match the load power requirements and the cable len...

Reviews: