8 - SETTINGS
The parameters of the LEDMASTER STUDIO 1 can be changed from the DIP switch
“SETTINGS”, or from a RDM controller (only in RDM mode, refer to RDM section for
details).
#
SETTING
DESCRIPTION
S1-S2
MODE
Selection of the operating mode:
- “00”=
DMX/RDM
, Device control from wired DMX interface (Refer
to DMX section for details)
- “01”=
Manual
, Allows user to control the output brightness from
the local rotary switch (Refer to Manual Dimming section
for details)
- “10”=
CRMX/RDM
, Device control from wireless CRMX interface.
(Refer to CRMX section for details)
- “11”=
Test
, Allows user to test the device when installing, without
any controller (Output brightness variation loop, indicators
blinking).
S3
DMX RESOLUTION
Switch between 8 bits and 16 bits DMX resolution for fine/coarse
adjustments:
- ”0” =
8 bits
- ”1” =
16 bits
S4-S5
PWM FREQUENCY
Output PWM frequency selection:
- “00”=
32kHz
- “01”=
16kHz
- “10”=
8kHz
- “11”=
4kHz
S6-S7
DMX FAIL
Select the behaviour in case of DMX stream interruption (lost
signal, DMX cable issue, controller Off …):
- ”00”=
Hold
(Hold the current/last valid DMX values)
- ”01”=
Black
(Forced blackout, turn off output)
- ”10”=
Man. dimming
(Apply the brightness output according
to the value set on the “Manual Dimming” Rotary switch.
Refer to MANUAL MODE section for details)
- ”11”=
Full
(Forced Full-On, turn on output)
S8
DMX FADING
Assigns an additional DMX channel for fading timing adjustment,
20ms steps, from ‘‘000’’ (no fading) to ‘‘255’’ (= 5s fading time)
S9-S10
DIMMING CURVE
Output dimming curve selection:
- “00”=
Linear
- “01”=
Logarithmic
- “10”=
Exponential
- “11”=
Custom
(optimized for 18,5W 12V AR111 LED spot at 32kHz)
Refer to DIMMING CURVE section for details.
9 - DMX
To enable the DMX feature, the device must be set in DMX mode (S1-S2 = “00”).
When DMX signal is received, the blue “DMX Data” indicator turns ON.
Use the three rotary switches to set the DMX address. In case an out of range
address is entered, the device will automatically assign the highest DMX address
usable.
Note: The DMX address “000” is reserved for RDM control. When “000” address is
selected,
the default DMX address is “001”
.