Exalux LEDMASTER STUDIO 1 User Manual Download Page 5

Protocols

DMX512-A & RDM (ANSI E.1.20) - RDM manufacturer ID: “0084h”

Universe

1

DMX frame rate

0,8-830Hz

DMX input/output

1x DMX input/Passthrough, 2x 5.08mm terminal block (green), 3 positions

DMX options

DMX resolution: 8 bits or 16 bits 

DMX fail: Hold, Black, Full or Manual setting 

DMX fading: On/Off

DMX CHARTS:

Addr

Addr+1

Addr+2

DMX - 8bits

Output brightness 

(0% to 100%)

-

-

DMX - 16bits

Output brightness 

(0% to 100%, MSB/Coarse dimming)

Output Brightness 

(LSB/Fine dimming)

-

DMX - 8bits + Fading

Output brightness 

(0% to 100%)

Fading 

(0s to 5s)

-

DMX - Fading

Output brightness 

(0% to 100%, Coarse dimming)

Output Brightness 

(Fine dimming)

Fading (0s to 5s)

10 - RDM

To enable the RDM control, the device must be set in DMX or CRMX mode (S1-S2 

= “00” or “10”) and 

the DMX address must be set to “000”

When the DMX address “000” is selected, DMX modes (resolution, fading) can be 

changed from RDM controller. In that case, values sets on the DIP switch settings 

do not necessarily correspond to the current operating mode.

The RDM features can be used on both wired DMX and wireless CRMX.

- RDM manufacturer identifier: «

0084h

». 

- RDM labels: ‘‘LEDMASTER STUDIO 1 DMX’’ & ‘‘LEDMASTER STUDIO 1 CRMX’’

- RDM sensors: input voltage & CRMX signal reception (for CRMX versions only)

The device supports the following RDM PIDs:

DISC_UNIQUE_BRANCH

DISC_MUTE

DISC_UN_MUTE

SUPPORTED_PARAMETERS

DEVICE_INFO

FACTORY_DEFAULTS

SOFTWARE_VERSION_LABEL

DMX_START_ADDRESS

IDENTIFY_DEVICE

DEVICE_MODEL_DESCRIPTION

MANUFACTURER_LABEL

SENSOR_DEFINITION

DEVICE_LABEL

DMX_PERSONALITY

DMX_PERSONALITY_DESCRIPTION

SLOT_INFO

SLOT_DESCRIPTION

SENSOR_VALUE

11 - CRMX RADIO INTERFACE

Standard / Technology

CRMX by LumenRadio™

Frequency

2.402 ~ 2.480 GHz

Antenna

Swivel whip omnidirectional, 2.4GHz 2.0dBi, SMA (SMA-F onboard, SMA-M on antenna)

RF Output

20 dBm (100mW) - ETSI compliant

RF Modulation

GFSK

End to end latency

< 5ms

Range

Up to 300m (depending on the transmitter and the environment) 

Interface

3x green LEDs for radio signal level, 1x pushbutton (hold 3s to unlink from transmitter)

Summary of Contents for LEDMASTER STUDIO 1

Page 1: ...er optional This dimmer is integrated in a standard DIN rail enclosure with 5 08mm pluggable terminal blocks for quick and easy set up The LEDMASTER STUDIO 1 is available in several versions which can...

Page 2: ...t only for AC versions DC Input only for DC versions DMX In Out Power LED indicator red Reset Unlink switch 2 4GHz SMA mount antenna only for CRMX versions 3x CRMX signal level LED indicators green on...

Page 3: ...not exceed 7 5A per contact on terminal blocks and cables In case of a load higher than 7 5A it is imperative to distribute the power on the four input and output pins 7 GENERAL SPECIFICATIONS AC Pow...

Page 4: ...viour in case of DMX stream interruption lost signal DMX cable issue controller Off 00 Hold Hold the current last valid DMX values 01 Black Forced blackout turn off output 10 Man dimming Apply the bri...

Page 5: ...DIP switch settings do not necessarily correspond to the current operating mode The RDM features can be used on both wired DMX and wireless CRMX RDM manufacturer identifier 0084h RDM labels LEDMASTER...

Page 6: ...s indicator turns off You can also unlink all linked receivers from the transmitter Signal level indicators Blinking no signal 1 LED poor reception 2 LEDs correct reception 3 LEDs excellent reception...

Page 7: ...is designed to be mounted onto a standard DIN rail 35mm width EN 60715 but wall mounted is another option Use the embedded plastic hook to attach or detach from the rail This device is delivered with...

Page 8: ...g it In case of non compliance devices may be damaged and the user may be injured Cable The section of power cables on AC and DC input output should match the load power requirements and the cable len...