![Exalt EX-5i Lite Installation & Management Download Page 32](http://html1.mh-extra.com/html/exalt/ex-5i-lite/ex-5i-lite_installation-and-management_2448770032.webp)
Exalt Communications, Inc.
EX-5i Installation & Management
5000005
19
2006-05-17
4.1.2 Indicator Overview
The following table provides detail of the indicators on the EX-5i.
Location/Label Type
Function
LINK 3-color
LED
Indicates RF link status:
Green Solid = Error-free connection (BER<10e-6)
Yellow Solid = Errored connection (10e-3>BER >10e-6)
Red Solid = No link (BER>10e-3)
Red Blink = No remote information available (when RMT
button is pressed and held)
Off = Improperly powered or fatal system failure
STATUS 3-color
LED
Indicates system status:
Green Solid = No alarm conditions (normal operation)
Yellow Solid = Alarm conditions, not traffic effecting
Yellow Blink Slow = In loopback (from this end)
Yellow Blink Fast = In loopback (at this end)
Red Solid = Alarm conditions, traffic affecting
Red Blink = No remote information available (when RMT
button is pressed and held)
Off = Improperly powered or fatal system failure
RADIO A
3-color LED
Indicates radio orientation:
Green Solid = Radio is configured as Radio A (source),
based on software setting (desired)
Green Blink = Radio is configured as Radio A (source),
based on temporary hardware configuration key
Off = Radio is configured as Radio B
DS3
3-color LED Green Solid = Connection present (clocking confirmed)
Yellow Solid = Connection present but unexpected
Red Solid = Connection present, clocking problem
Red Blink = No connection present, interface enabled
Off = Interface/alarm is disabled, no connection present
ETHERNET
MAIN/AUX
Left Corner
Green LED Solid/Blinking = Data is present
Off = No data present or interface/alarm is disabled
ETHERNET
MAIN/AUX
Right Corner
Green LED Solid = Negotiated @ 100Mbps
Blink = Negotiated @ 10Mbps
Off = No connection or interface/alarm is disabled
T1/E1
Left Corner
Green LED Solid = Connection present (clocking confirmed)
Blink Fast = Connection present, coding/clock problem
Blink Slow = Connection present but unexpected
Off = No connection/clock or interface/alarm is disabled
T1/E1
Right Corner
Green LED Solid = In a loopback state
Blink Fast = AIS (automatic indication signal) is active
Off = No loopback or AIS activity or interface/alarm is disabled
RMT
Amber LED Off = Remote end Link & Status LEDs are both green