This section is intended to provide a brief familiarization of the connectors, controls and
indicators on the device. More details about each item are found in other sections of this
document. The EX-5i front panel is shown here:
Figure 4-4:
Front Panel
4.1.1 Connector Overview
The following table provides detail of the connectors in the center of the front panel of the EX-
5i. Detailed pin structures for each connector can be found in Appendix D.
Figure 4-5:
Primary Front Panel Connectors
Table 4-1:
Connectors
Label Type
Gender
Function
Antenna
N
F
Transmission line connection to antenna
DS3 (In/Out)
BNC
F
Primary ports for User DS3 circuits to traverse link
T1/E1
(1-4)
RJ-48C
F
Primary ports for User T1 or E1 circuits to traverse
link
Ethernet
(Main/Aux)
RJ-45
F
Primary ports for user Ethernet and/or management
data (10BaseT or 100BaseT) to traverse link
Sync
(In/Out)
RJ-45
F
External radio synchronizing source (e.g. GPS) input
and output
Console
9-pin sub-D
F
Management port (serial) for PC/PDA for Command
Line Interface (CLI) communications
Alarms 9-pin
sub-D F
External alarm inputs and outputs
GND
(Ground)
Bantam
F
Common (return) voltmeter test point for measuring
received signal level
RSL
Bantam
F
Voltmeter test point for measuring received signal
level
20-60VDC
6-pin Modular
M
DC power input from DC source or AC adapter
(Ground)
Threaded (M5)
Receptacle
F
Chassis ground connection (M5 x 0.8 thread)
ANTENNA
DS3
OUT
IN
RSL
CONSOLE
ETHERNET
AUX
T1/E1
SYNC
MAIN
IN
1 2
3
OUT
4
ALARM
GND
LINK
STATUS
RADIO A
DS3
RMT
- ++ -
20-60 VDC