Familiarization with the s-Series Radios
The Exalt s-Series radios utilize frequency division duplex (FDD) radio transmission. This means that
the transmitted signal in each direction uses a different center frequency, separated by a fixed
Transmit/Receive spacing. As such, there is a designated ODU for the ‗High‘ transmitter frequency,
and a matching paired ODU for the ‗Low‘ center frequency. Generally, the licensing/coordination
agency will designate which transmitter should be installed at which end of the link. The IDUs are
independent of frequency and may be interchanged at either end of the link.
The frequency pair is controlled by the IDU and the tunable frequency range is determined by the
ODU that is connected. For some frequency bands, there is more than one ODU pair to cover the
entire band, so each ODU pair may be limited to tune only over a portion of the band. Exalt
recommends using the Exalt GUI for radio configuration of the frequency and other parameters. This
interface requires a computer with an Ethernet port and web browser software, such as Microsoft
Internet Explorer 5.0 or above. See
for details on how to connect to
and use the browser-based GUI interface.
Shipping Box Contents
A complete link or
hop
consists of two ODUs (one high, one low) and two IDUs.
The ODUs are individually boxed and ready to install onto a direct-mount antenna or remote
mounting bracket.
The IDUs are individually boxed, each box contains the following items:
Indoor unit (IDU)
AC adapter with power cord
Accessory kit:
Rack mount flanges
Flange mounting hardware (4 x M4 screws; 4 x M4 wave washers)
DC power connector (1)
Grounding hardware (1 x M5 screw; 1 x M5 wave washer; 2 x M5 flat washers)
Quick start guide
Product registration card
Inspect the outer packaging and the contents of the boxes upon receipt. If you suspect any shipping
damage or issues with the contents, contact Exalt Customer Care.
Note:
Register your system as soon as possible. A 2-year Warranty period applies to products
registered within 90 days of purchase. The Warranty period is reduced to 1-year for
unregistered products and products registered after the first 90 days. See
Initial Configuration and Back-to-Back Bench Test
Every Exalt digital microwave radio goes through extensive quality testing and performance
evaluation over the full operating temperature range prior to shipment. However, before installation,
it is strongly advised to perform several tests and tasks that are much more difficult to perform once