background image

7

Employer must enforce compliance with the safety warnings and all other
instructions contained in this manual.

Keep this manual available for use by all people assigned to use this tool.

For personal safety and proper operation of this tool, read and understand
tool labels and manual. Failure to follow warnings could result in DEATH or
SERIOUS INJURY. Read and follow all of these instructions carefully.

Ex-Cell Model ENS100 is designed to install generic 18 ga. narrow (

1

/

4

")

crown staples of various lengths from 

1

/

2

" to 1" long. Narrow crown staples

are loaded into the magazine from the bottom.

Ex-Cell Model ENS150 is designed to install generic 18 ga. narrow (

1

/

4

")

crown staples of various lengths from 

1

/

2

" to 1

1

/

2

" long. Narrow crown

staples are loaded into the magazine from the bottom.

Ex-Cell stapling tools are compact, lightweight, high performance tools
designed for molding, interior trim, paneling, cabinetry, picture/mirror frames
and crafts. Features include jam release mechanism, tool free adjustable
exhaust, fastener reload indicator, safety positioned on rear of nose and a
removable rubber nose cushion.

1) Stapler

3) Air Tool Oil Bottle

2) Staples

4) Owner's Manual

POWER SOURCE

This tool is designed to operate on clean, dry, compressed air at regulated
pressures between 70 and 110 PSI (Pounds per Square Inch)(4.8 to 7.6 BAR).
The preferred system would include a filter, a pressure regulator, and an
automatic oiler located as close to the tool as possible, within 15 ft/4.6 m is
ideal. 

The tool is equipped with a 

1

/

4

"

male “quick connector”.

All compressed air contains moisture and other contaminates that are
detrimental to internal components of the tool. An air line filter will remove
most of these contaminates and significantly prolong the life of the tool. If an
in-line oiler is not available: place five or six drops of Air Tool Oil into the tool’s
air inlet at the beginning of each workday.

EMPLOYER’S RESPONSIBILITIES

FUNCTIONAL DESCRIPTION

CARTON CONTENTS 

Summary of Contents for Ex-Cell A05983

Page 1: ...Power Company Part No A05983 07 22 04 Owners Manual for models ENS100 ENS150 Staplers Record All Information and attach sales receipt here for future reference Purchase Date _________________________...

Page 2: ...bre d ordre TABLE OF CONTENTS SAFETY GUIDELINES AND INSTRUCTIONS 3 GENERAL SAFETY RULES 4 6 FUNCTIONAL DESCRIPTION 7 PREPARING THE TOOL 8 OPERATING INSTRUCTIONS 9 10 MAINTENANCE 10 SERVICE 11 TROUBLES...

Page 3: ...ways be followed to reduce the risk of personal injury Improper operation maintenance or modification of tools or equipment could result in serious injury and property damage There are certain applica...

Page 4: ...hanism is bumped while the trigger is depressed 4 Choice of triggering method is important Check manual for triggering options See Using the Tool section of this manual 5 Never point tool at yourself...

Page 5: ...ever use tool if safety trigger or springs are inoperable missing or damaged Do not alter or remove safety trigger or springs Make daily inspections for free movement of trigger and safety mechanism F...

Page 6: ...n With Contact Actuation tools an unwanted fastener will be fired if the safety mechanism is allowed to recontact work surface before trigger is released 26 Do not drive fasteners on top of other fast...

Page 7: ...ior trim paneling cabinetry picture mirror frames and crafts Features include jam release mechanism tool free adjustable exhaust fastener reload indicator safety positioned on rear of nose and a remov...

Page 8: ...th points up in the magazine channel B Fig 20 NOTE Staples are loaded from the bottom 4 Push magazine core closed Fig 21 5 Observe the low fastener indicator A Fig 22 and reload as needed 6 Adjust dir...

Page 9: ...astener is driven This single sequential actuation method provides the most accurate fastener placement Disconnect tool from air supply before performing maintenance clearing a jammed fastener leaving...

Page 10: ...ews tight Loose screws can cause personal injury or damage tool If tool is used without an in line oiler place 5 or 6 drops of Air Tool Oil into the air inlet of the tool at the beginning of each work...

Page 11: ...ply before performing any Service Procedure SYMPTOM PROBLEMS SOLUTIONS 1 Air leak near top of Loose screws Tighten screws tool or in trigger area Worn or damaged Install Overhaul Kit o rings or seals...

Page 12: ...oes not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company THIS WARRANTY DOES NOT COVER Merchandise sold as reconditioned...